2022
DOI: 10.1016/j.talanta.2021.122858
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic paper device with on-site heating to produce reactive peroxide species for enhanced smartphone enabled chemiluminescence signal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(12 citation statements)
references
References 30 publications
0
12
0
Order By: Relevance
“…A validated smartphone coupled µPAD achieved a LOD of 1.1 mg/kg for nitrite in meat (Trofimchuk et al, 2020). Another temperature-based approach demonstrated a wide linear range (50 nM to 1 M) and low LOD (35 nM) for H 2 O 2 with lower sample and reagent consumption (Kumar et al, 2022). The inclusion of another adulterant benzoic acid in milk can cause diarrhea, asthma, convulsions, and abdominal pain (Hussain et al, 2020).…”
Section: Detection Via Smartphone Appsmentioning
confidence: 99%
“…A validated smartphone coupled µPAD achieved a LOD of 1.1 mg/kg for nitrite in meat (Trofimchuk et al, 2020). Another temperature-based approach demonstrated a wide linear range (50 nM to 1 M) and low LOD (35 nM) for H 2 O 2 with lower sample and reagent consumption (Kumar et al, 2022). The inclusion of another adulterant benzoic acid in milk can cause diarrhea, asthma, convulsions, and abdominal pain (Hussain et al, 2020).…”
Section: Detection Via Smartphone Appsmentioning
confidence: 99%
“…They can be classified based on the flow control mechanisms into flow injection devices with the differential pressure flow mode, 15 microfluidic paper-based analytical devices (μPADs) driven by capillary force, 16 microchip capillary electrophoresis (MCE) devices using electrokinetic flow, 17 and digital microfluidics (DMF) employing electric fields for droplet control. 18 μPADs have been widely exploited to detect glucose, 19-21 lactate, 16,22 or H 2 O 2 23 using CL due to their advantages in fluid flow control, low cost, and disposability. The capability in fluid flow enabled by the capillary force facilitated the easy control of multiple reagents and reaction sequences on paper devices.…”
Section: Introductionmentioning
confidence: 99%
“…Numerous paper-based chemiluminescence devices have been developed, with a predominant focus on metabolic markers in food, 23 blood, 20 and urine 21 samples. For instance, Kumar et al developed a 3D printed microfluidic paper-based CL analyzer for H 2 O 2 in milk, which had a LOD of 35 nM and a linear range of 0.05-1 μM.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The determination of analytes in paper-based analytical devices (PAD) can be performed using electrochemical, chemiluminescence, electrochemiluminescence, and colorimetric detection. , For this platform, colorimetric detection is of great interest because it is a simple methodology based on chromogenic reactions within the PAD reaction zones. The results can be visually detected by a (i) binary response (positive or negative) in a qualitative approach; (ii) comparison with a colorimetric scale obtained by a standard (semiquantitative approach); or (iii) quantitatively through the use of mathematical models in which the product color intensity is proportional to the chemical species concentration to be quantified from the digitalized image …”
Section: Introductionmentioning
confidence: 99%