2006
DOI: 10.1109/tps.2005.863570
|View full text |Cite
|
Sign up to set email alerts
|

Microsecond plasma opening switches in externally applied magnetic field

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2007
2007
2013
2013

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 30 publications
0
4
0
Order By: Relevance
“…In accordance with [2,3], the radial gap between the electrodes of each POS is ΔR = 2.5 cm, the induction of the external quasi stationary magnetic field, which is created by a foreign source is В Z = 6-8 kG; this field is produced by two oppositely connected solenoids 7. High voltage electrode 5 is made of ~5 mm thick cop per, thus allowing separation of the magnetic fields that are created in the gaps of the outer and inner POSs.…”
Section: Electronics and Radio Engineeringmentioning
confidence: 89%
See 1 more Smart Citation
“…In accordance with [2,3], the radial gap between the electrodes of each POS is ΔR = 2.5 cm, the induction of the external quasi stationary magnetic field, which is created by a foreign source is В Z = 6-8 kG; this field is produced by two oppositely connected solenoids 7. High voltage electrode 5 is made of ~5 mm thick cop per, thus allowing separation of the magnetic fields that are created in the gaps of the outer and inner POSs.…”
Section: Electronics and Radio Engineeringmentioning
confidence: 89%
“…A one capacitor based supply module contains capacitor 2 and six 50 Ω КВИ 110 cables, which connect it through three channel spark gap 3 to three lead ins 8 of high voltage electrode 5. The most efficient scheme of a POS with an external magnetic field is used [2,3]. The technique for its calculation and matching to the liner is presented in [4,5].…”
Section: Scheme Of a Pos Based Generator With An External Magnetic Fieldmentioning
confidence: 99%
“…Experiments of this type were performed on the model [3]. The wire resistance dynamics was studied at different values of the load inductance and magnetic field in the absence of a vacuum gap.…”
Section: Experiments With a Low Inductance Loadmentioning
confidence: 99%
“…The program of the development of ultrahigh power generators for experiments in the field of iner tial controlled thermonuclear fusion (the MOL facility in the Baikal program [1], magnetic explosion gener ators [2]) suggests using a plasma current source (POS) in an external magnetic field, which is a longi tudinal magnetic field created by an external source [3]. The POS consists of two coaxial electrodes that are included in the circuit of an inductive storage.…”
Section: Introductionmentioning
confidence: 99%