2014
DOI: 10.1016/j.msec.2014.07.002
|View full text |Cite
|
Sign up to set email alerts
|

Microstructure and cytotoxicity evaluation of duplex-treated silver-containing antibacterial TiO2 coatings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
39
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(41 citation statements)
references
References 48 publications
2
39
0
Order By: Relevance
“…The addition of Ag enhanced the antimicrobial efficacy against both microorganisms due to Ag ions released from the coating. Similar antimicrobial effect vs E. coli and S. aureus was found by testing porous TiO 2 coatings on Ti surfaces containing different Ag concentrations (ranging from 0% to 15%) . The same research group in a further study reported the activity of these Ag‐TiO 2 coatings for long term (28 days) .…”
Section: Antimicrobial Coatingssupporting
confidence: 65%
“…The addition of Ag enhanced the antimicrobial efficacy against both microorganisms due to Ag ions released from the coating. Similar antimicrobial effect vs E. coli and S. aureus was found by testing porous TiO 2 coatings on Ti surfaces containing different Ag concentrations (ranging from 0% to 15%) . The same research group in a further study reported the activity of these Ag‐TiO 2 coatings for long term (28 days) .…”
Section: Antimicrobial Coatingssupporting
confidence: 65%
“…This method is based on anodic oxidation of metal in an electrolyte, at voltages that lead to plasma micro-discharges at the electrode surface [6][7][8] . In general, MAO coatings fabricated on Ti alloys are composed of anatase and rutile titanium oxide (TiO 2 ), and the coatings obtained from aluminate-containing electrolytes also contain aluminum titanate (Al 2 TiO 5 ) [4,[9][10][11][12] . The high hardness of such coatings leads to high wear resistance, however, exhibits relatively low wear resistance and high friction coefficients under non-lubrication conditions.…”
Section: Introductionmentioning
confidence: 99%
“…In a similar study, Shin et al have found no cytotoxic response at low AgNPs concentration (0,0.1 g/l) in (MC3T3‐E1) cell line, but increasing concentration (0.3 and 0.5 g/L) had a negative impact on cell proliferation . Zhang et al analyzed cytotoxicity behavior of PEO TiO 2 layer using the mouse preosteoblast cells on sputtering‐deposited AgTi surface with Ag content varying 0, 0.95, 1.36, and 1.93 wt %. PEO surfaces with Ag content 1.36 wt % and above were reported to be cytotoxic …”
Section: Antibacterial Coatings Through Peomentioning
confidence: 99%