2016
DOI: 10.1088/0022-3727/49/43/435202
|View full text |Cite
|
Sign up to set email alerts
|

Microwave air plasmas in capillaries at low pressure II. Experimental investigation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
15
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 52 publications
1
15
0
Order By: Relevance
“…and O(3s 3 S 0 ) using the emission cross sections from Itikawa (2009), Kanik et al (2003). This choice of cross sections is the same as in Fiebrandt et al (2020) and in Stancu et al (2016) and is similar to the one in Caplinger and Perram (2020) We should notice that this is the dominant ion in the studied plasma (Viegas et al 2020).…”
Section: O Atom Collisional-radiative Model In Co 2 Conversion Plasmamentioning
confidence: 99%
“…and O(3s 3 S 0 ) using the emission cross sections from Itikawa (2009), Kanik et al (2003). This choice of cross sections is the same as in Fiebrandt et al (2020) and in Stancu et al (2016) and is similar to the one in Caplinger and Perram (2020) We should notice that this is the dominant ion in the studied plasma (Viegas et al 2020).…”
Section: O Atom Collisional-radiative Model In Co 2 Conversion Plasmamentioning
confidence: 99%
“…The species taken into account are O 2 (X) and O 3 (X) groundstate molecules, O 2 (a) and O 2 (b) electronically excited metastable states, O 3 (exc) vibrationally excited molecules, ground-state O( 3 P) and metastable O( 1 D) atoms, and O + 2 , O + and O − ions. The kinetic scheme was previously used to study inductive coupled plasmas [44], and very similar schemes were used to successfully describe microwave [45,46] and DC [47,48] discharges. The deterministic simulations are performed using the 0-D chemistry solver of the LisbOn Kinetics (LoKI) tool suite [49][50][51], for the same conditions and using the same kinetic scheme as in the KMC calculations.…”
Section: Validationmentioning
confidence: 99%
“…The simulations presented in this study were carried out using the self-consistent LoKI numerical simulation tool, a global, volume averaged (0D) kinetic model introduced by Loureiro (1997, 1999) and successfully used for kinetic modelling of diverse plasma conditions (Kutasi et al 2010, Marinov et al 2013, Kutasi et al 2016, Stancu et al 2016. In this work the description of the oxygen kinetics is extended by including the calculation of the VDF of O 2 ground state molecules, which is detailed in section 3.2.…”
Section: Overview Of the Modelmentioning
confidence: 99%