2019
DOI: 10.1109/tap.2019.2908267
|View full text |Cite
|
Sign up to set email alerts
|

Microwave-Induced Thermoacoustic Imaging for Embedded Explosives Detection in High-Water Content Medium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(4 citation statements)
references
References 54 publications
0
4
0
Order By: Relevance
“…In biomedical imaging, MTAI is widely used in anatomical, functional, molecular, and histological studies due to its high resolution, deep imaging depth and minimal biohazards. Patch et al [29][30][31][32][33][34], Kruger et al [5,[35][36][37][38][39][40][41][42], Xing et al [11,17,[43][44][45][46][47][48][49][50][51][52][53][54][55][56][57][58], Wang et al [12,13,15,16,[59][60][61][62][63][64][65][66], Jiang et al [4,[67][68][69][70]…”
Section: Introductionmentioning
confidence: 99%
“…In biomedical imaging, MTAI is widely used in anatomical, functional, molecular, and histological studies due to its high resolution, deep imaging depth and minimal biohazards. Patch et al [29][30][31][32][33][34], Kruger et al [5,[35][36][37][38][39][40][41][42], Xing et al [11,17,[43][44][45][46][47][48][49][50][51][52][53][54][55][56][57][58], Wang et al [12,13,15,16,[59][60][61][62][63][64][65][66], Jiang et al [4,[67][68][69][70]…”
Section: Introductionmentioning
confidence: 99%
“…The recent rise in global terrorism means that the use of these methods to detect explosives should be both sensitive and low cost. Trained bees [2], sniffer dogs [3], surface-enhanced Raman spectroscopy [4,5], mass spectroscopy [6], X-ray imaging [7], thermal neutron analysis [8] and microwave-induced thermoacoustic imaging [9] have been proposed as suitable methods for the detection of these explosives. Although all of the abovementioned methods offer advantages, there are many improvements to be made to the response speed, cost, sensitivity and in-field applications of explosive sensors [10,11].…”
Section: Introductionmentioning
confidence: 99%
“…Microwave-induced thermoacoustic tomography (TAT) utilizes pulsed microwaves to generate ultrasonic signals. [12][13][14][15][16][17][18][19] As a hybrid modality, TAT combines the advantages of high electromagnetic contrast and high ultrasonic resolution. In recent years, TAT has been developed in many aspects, such as thermoacoustic mesoscopy, compressive sensing TAT, thermoacoustic endoscopy, multimodality imaging, thermoacoustic molecular imaging, and low-cost portable TAT systems.…”
Section: Introductionmentioning
confidence: 99%
“…Microwave‐induced thermoacoustic tomography (TAT) utilizes pulsed microwaves to generate ultrasonic signals 12–19 . As a hybrid modality, TAT combines the advantages of high electromagnetic contrast and high ultrasonic resolution.…”
Section: Introductionmentioning
confidence: 99%