1997
DOI: 10.1109/61.634196
|View full text |Cite
|
Sign up to set email alerts
|

Mid-point siting of FACTS devices in transmission lines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
32
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 94 publications
(32 citation statements)
references
References 11 publications
0
32
0
Order By: Relevance
“…machines 1 & 2) and improved the transient stability of the test system after disturbances (faults or heavy loading), a LQR based CSC-STATCOM is connected at the mid-point of transmission line (at bus B2). Achieve maximum efficiency; CSC-STATCOM is connected at the midpoint of transmission line, as per [28]. The two hydraulic generating units are assembled with a turbine-governor set and excitation system, as explained in [1].…”
Section: Power System Under Studymentioning
confidence: 99%
“…machines 1 & 2) and improved the transient stability of the test system after disturbances (faults or heavy loading), a LQR based CSC-STATCOM is connected at the mid-point of transmission line (at bus B2). Achieve maximum efficiency; CSC-STATCOM is connected at the midpoint of transmission line, as per [28]. The two hydraulic generating units are assembled with a turbine-governor set and excitation system, as explained in [1].…”
Section: Power System Under Studymentioning
confidence: 99%
“…Equations (8) and (12) are the basic design equations of the proposed harmonic-suppressed TCR. Using these equations, the passive elements of the harmonic-suppressed TCR can be expressed in terms of its reactor inductance as follows:…”
Section: Controlling Circuitmentioning
confidence: 99%
“…As a result, it requires the installation of harmonic filters at its location [9]- [11]. TCRs are considered to be an important application of what is known as Flexible Alternative of Current Transmission Systems (FACTS) devices, which represent the recent application of power electronics in transmission systems [12]- [16]. FACTS devices are designed to satisfy the real time demands of power systems.…”
Section: Introductionmentioning
confidence: 99%
“…compensation depending upon their compensating strategies. It has been proved that shunt FACTS devices give maximum benefit due to their stabilized voltage support when sited at the mid-point of the transmission line [3].…”
Section: Introductionmentioning
confidence: 99%