Midbrain transcranial sonography in Korean patients with Parkinson's disease

Abstract: Transcranial sonography (TCS) is potentially useful for the diagnosis of Parkinson's disease (PD). However, studies on TCS have so far been restricted to European populations. To investigate the efficacy of TCS in Korean PD patients and its correlation with the clinical features, we carried out midbrain TCS in 43 PD patients and 35 normal controls and evaluated the area of the substantia nigra (SN) hyperechogenicity and its ratio to the area of the whole midbrain. In 16 subjects (21%), TCS was unsuccessful due… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
35
0
3

Year Published

2009
2009
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 62 publications
(43 citation statements)
references
References 18 publications
5
35
0
3
Order By: Relevance
“…SN planimetric measurement has been shown to be accurate and reliable with little inter-rater variability [7]. To date different cut-offs values have been used and proposed to differentiate normal (SN−) and hyperechogenic (SN+) according to different devices and protocols [14][15][16][17].…”
Section: Brainstem Structuresmentioning
confidence: 99%
“…SN planimetric measurement has been shown to be accurate and reliable with little inter-rater variability [7]. To date different cut-offs values have been used and proposed to differentiate normal (SN−) and hyperechogenic (SN+) according to different devices and protocols [14][15][16][17].…”
Section: Brainstem Structuresmentioning
confidence: 99%
“…However, some authors calculated the mean of both sides [31][32][33]. Mostly, the area of increased signal intensity was measured to estimate whether the SN was normal or not.…”
Section: ■ Overviewmentioning
confidence: 99%
“…In the case of a narrow transtemporal bone window, the transducer should be slightly shifted caudally -simultaneously with the upward tilting maneuver -in order to keep the bone window. Even if the bone window is poor, the pineal gland is mostly visible due General Electric/Logiq 9 3S/2.5 ≥ 0.20 Fedotova et al [22] Philips/HDI 5000 SonoCT P2 -4/2.5 ≥ 0.20 Kim et al [23] Philips/HP Sonos 5500 S4/2.0 -2.5 ≥ 0.20 ≥ 0. 27 Mehnert et al [17] Hagenah et al [18] Siemens/Acuson Antares PX4 -1/2.5 ≥ 0.24 ≥ 0.30 Van de Loo et al [10] Glaser et al [24] Siemens/Sonoline Elegra 2.5PL20/2.6 ≥ 0.20 ≥ 0.…”
Section: Visualization and Assessmentmentioning
confidence: 99%