2011
DOI: 10.1016/j.vibspec.2011.01.003
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturized integrated evanescent field IR-absorption sensor: Design and experimental verification with deteriorated lubrication oil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 22 publications
0
11
0
Order By: Relevance
“…Sensor systems researched have included infrared [2][3][4], hyperspectral [5], resonating [6][7][8][9][10], and electrochemical [11][12][13][14][15][16]. These sensors have attempted to monitor oil conditions such as viscosity [7,8,12,17]; acidity [6,[14][15][16]18]; fuel, water, or antifreeze contamination [3]; and antioxidants [11,13].…”
Section: Introductionmentioning
confidence: 99%
“…Sensor systems researched have included infrared [2][3][4], hyperspectral [5], resonating [6][7][8][9][10], and electrochemical [11][12][13][14][15][16]. These sensors have attempted to monitor oil conditions such as viscosity [7,8,12,17]; acidity [6,[14][15][16]18]; fuel, water, or antifreeze contamination [3]; and antioxidants [11,13].…”
Section: Introductionmentioning
confidence: 99%
“…Sensor systems studied have included electromechanical (Cheek and Mowery, 1989;Duchowski and Mannebach, 2006;Price and Clarke, 1991;Soleimani et al, 2013;Wang et al, 1994;Wang, 2002) and resonating sensors (Agoston et al, 2005;Jakoby et al, 2003;Milpied et al, 2010;Mohammed and Hassan, 2013). Infrared (Blanco et al, 1998;Borin and Poppi, 2005;Kasberger et al, 2011) and hyperspectral (Lulu et al, 2014) spectroscopy techniques have also been used. The oil conditions these sensors attempted to monitor were acidity (Agoston et al, 2005;Moon et al, 2006;Soleimani et al, 2013;Wang et al, 1994;Wang, 2002), antioxidants (Cheek and Mowery, 1989;Price and Clarke, 1991), viscosity (Duchowski and Mannebach, 2006;Jakoby et al, 2003;Schmitigal and Moyer, 2005), and contaminants of fuel, water, or antifreeze (Borin and Poppi, 2005).…”
mentioning
confidence: 99%
“…Optimized values for the thickness and the length of the waveguide can be found by calculating the maximum change of the normalized power of the guided mode. This allows for defining a sensitivity (figure of merit) using the following equation [16],…”
Section: Optimum Waveguide Designmentioning
confidence: 99%