2004
DOI: 10.1093/bja/aeh077
|View full text |Cite
|
Sign up to set email alerts
|

Minimum alveolar concentration (MAC) of xenon in intubated swine

Abstract: MAC(Xe) in swine was calculated by extrapolation of a logistic regression model. Its theoretical value is 119 vol. %.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
11
0
1

Year Published

2005
2005
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(14 citation statements)
references
References 7 publications
2
11
0
1
Order By: Relevance
“…In this first study in pigs < 24 h old, the MAC for sevoflurane at normothermia was 4.1%, which is higher than a previously published result of 2.12% in 6 –day‐old pigs . MAC for xenon in these newborn pigs at normothermia (120%) was similar to that previously reported in young, 28–35 kg pigs (119%) indicating a reduced effect of age on MAC for xenon in pigs. The determination of xenon MAC in the older pigs was done in a different laboratory.…”
Section: Discussionsupporting
confidence: 71%
See 2 more Smart Citations
“…In this first study in pigs < 24 h old, the MAC for sevoflurane at normothermia was 4.1%, which is higher than a previously published result of 2.12% in 6 –day‐old pigs . MAC for xenon in these newborn pigs at normothermia (120%) was similar to that previously reported in young, 28–35 kg pigs (119%) indicating a reduced effect of age on MAC for xenon in pigs. The determination of xenon MAC in the older pigs was done in a different laboratory.…”
Section: Discussionsupporting
confidence: 71%
“…MAC for xenon (eliminating gross movement in 50% of subjects in response to a defined pain stimulus) is unknown both in neonatal humans and in pigs. It has been studied in adult humans and pigs, being reported as 119% in pigs . MAC is usually influenced by species, age and body temperature .…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Unlike the vapor agents they are relatively impotent as general anesthetics and require high concentrations to achieve 1 MAC (257,483,757). Indeed 1 MAC for nitrous oxide exceeds 100 Vol% at standard atmospheric pressure and this agent could only be used as a sole anesthetic in a hyperbaric chamber (473,474,587,617,655).…”
Section: Inhalational Agents: Gaseous Anestheticsmentioning
confidence: 99%
“…При разработке анестезиологического обеспече ния программы ранней активизации (РА) больных, опе рируемых с искусственным кровообращением (ИК) по поводу ишемической болезни сердца (ИБС), вполне за кономерен интерес к использованию ксенона (Хе). Его применение представляется перспективным в свете данных о минимальных или отсутствующих влияниях на центральную гемодинамику (ЦГД) и функцию ише мизированного миокарда, а также о быстром и ком фортном пробуждении больных после ксеноновой ане стезии [1][2][3][4][5][6][7][8].…”
unclassified