Abstract:Experimental investigation of the characteristics of the interface between a base laminate [08] T and a repair laminate [08] T was carried out through Mode II fracture tests, compliance calibration tests, and microscopic observations. The material used for manufacturing the test samples is unidirectional carbon fiber prepreg (Newport Composites NCT-301 graphite/epoxy). The laminate lay-up used in all experiments was [016] T.The specimens were subjected to variations in the autoclave pressure in the repair curi… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.