Abstract:Output-Error (OE) System Identification is used to estimate the nonlinear behavior of an activated sludge process (ASP) in a Wastewater Treatment Plant (WWTP). The aim is to identify dynamic models to reproduce the effect of different plant dynamics. How the dissolved oxygen concentration of the aerobic tank affect the effluent ammonia concentration and how the internal recirculation affect the nitrate concentration of the anoxic tank is studied. The best fit of the model is estimated by varying the model orde… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.