2013 IEEE Biomedical Circuits and Systems Conference (BioCAS) 2013
DOI: 10.1109/biocas.2013.6679687
|View full text |Cite
|
Sign up to set email alerts
|

Modeling a safety-related system for continuous non-invasive blood pressure monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…The design of medical systems towards more accuracy and resiliency is quite challenging, and to mitigate, in the recent past decade, developed and used few techniques like data fusion techniques [1], [3], [12], [16], [21], Artificial Intelligence (AI) based techniques [17]- [23] and correlation techniques [7]- [9], [23], [24]. However, all these techniques will have its limitations and lack in mitigating the challenges, like accurate identification and separation of the apt signal data for data analytics to extract the artifacts, identification of inaccurate signal data, and finding the root cause of the faults like systemic or random failures towards determining the health of the medical systems.…”
Section: Background and Motivation A Related Work And Motivationmentioning
confidence: 99%
See 2 more Smart Citations
“…The design of medical systems towards more accuracy and resiliency is quite challenging, and to mitigate, in the recent past decade, developed and used few techniques like data fusion techniques [1], [3], [12], [16], [21], Artificial Intelligence (AI) based techniques [17]- [23] and correlation techniques [7]- [9], [23], [24]. However, all these techniques will have its limitations and lack in mitigating the challenges, like accurate identification and separation of the apt signal data for data analytics to extract the artifacts, identification of inaccurate signal data, and finding the root cause of the faults like systemic or random failures towards determining the health of the medical systems.…”
Section: Background and Motivation A Related Work And Motivationmentioning
confidence: 99%
“…However, all these techniques will have its limitations and lack in mitigating the challenges, like accurate identification and separation of the apt signal data for data analytics to extract the artifacts, identification of inaccurate signal data, and finding the root cause of the faults like systemic or random failures towards determining the health of the medical systems. In-depth studies [5], [10]- [12], [16], [24] show that potential faults in sensors or related system design factors may cause the biosignal embedded with external environmental faults.…”
Section: Background and Motivation A Related Work And Motivationmentioning
confidence: 99%
See 1 more Smart Citation
“…The signal has been used in the study of detecting and diagnosing HR and HR variability (HRV) , blood oxygen saturation (SpO 2 ) [6], blood pressure , respiratory rate , vascular assessment , cardiac output , and venous refilling time . Research has also shown that multisite PPG (ears, thumbs, and big toes) measurement is useful for vascular disease detection and measuring blood glucose levels . Multisite PPG compares two PPG signal sequences recorded at anatomically symmetric sites on the human body (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, researchers need methods to collect PPG information during long time periods and from multiple sites with high accuracy for the best diagnosis. Several PPG instruments have been developed, both custom‐made and application‐specific . Recently, communications and information technologies have aided significantly in the improvement and expansion of the PPG signal acquisition system.…”
Section: Introductionmentioning
confidence: 99%