Modeling air conditioner load for power system studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0
2

Year Published

2005
2005
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 53 publications
(22 citation statements)
references
References 7 publications
0
20
0
2
Order By: Relevance
“…Their availability depends a lot on the appliance considered: whereas electric space heaters have a good availability (0.4 oa r o1) due to the fact that they are turned on for long periods of time, washing machines have a very limited one (a r o0.1) as they are typically turned on once every two days for two hours [48,49]. Similar rationale applies for their predictability [41,50]. Heat pumps coupled with thermal energy storage stand out in this category; their max power temporal ratio can reach up to 3 h without any inconvenience for end-users [51], making those units suited for longer grid services such as peak shaving.…”
Section: Consuming Der: Residential Loadsmentioning
confidence: 87%
“…Their availability depends a lot on the appliance considered: whereas electric space heaters have a good availability (0.4 oa r o1) due to the fact that they are turned on for long periods of time, washing machines have a very limited one (a r o0.1) as they are typically turned on once every two days for two hours [48,49]. Similar rationale applies for their predictability [41,50]. Heat pumps coupled with thermal energy storage stand out in this category; their max power temporal ratio can reach up to 3 h without any inconvenience for end-users [51], making those units suited for longer grid services such as peak shaving.…”
Section: Consuming Der: Residential Loadsmentioning
confidence: 87%
“…This situation leads not only to a high current consumption scenario, but also to a high increase of the reactive power demand. This type of behaviour can explain some of the voltage collapses that took place in Japan [4,5].…”
Section: Air Conditioning Appliances As Electric Loadsmentioning
confidence: 99%
“…• Voltage collapse [4,5]. The voltage reduction at the terminals of the residential air conditioning appliances reduces the electromagnetic motor torque driving the compressor.…”
Section: Air Conditioning Appliances As Electric Loadsmentioning
confidence: 99%
“…Frequency control using variation in average power consumption of the loads is achieved by switching those on/off with appropriate duty cycles [10], [11]. This is also predicated on the fact that the potential candidate loads for DSM e.g., air conditioners, especially, the ones supplied through adjustable speed drives exhibit a constant power characteristics over a wide voltage range [12] which rules out any possibility of continuous control. Moreover, if the load is operating at its rated capacity, the average power consumption of the load can only be reduced, not increased through on/off control.…”
Section: Introductionmentioning
confidence: 99%