2009
DOI: 10.3938/jkps.55.1640
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of a digital couch for a proton treatment planning system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…A further complication arises if the treatment couch differs from the couch used for TPS simulation. 64 Therefore, a set of physical and radiologic tests should be carried out to ensure the uniformity of the treatment couches to be used. The first step is to acquire a CT scan of each couch and inspect the image set for inhomogeneities resulting from the fabrication process (there should not be any).…”
Section: A Treatment Tabletopsmentioning
confidence: 99%
See 2 more Smart Citations
“…A further complication arises if the treatment couch differs from the couch used for TPS simulation. 64 Therefore, a set of physical and radiologic tests should be carried out to ensure the uniformity of the treatment couches to be used. The first step is to acquire a CT scan of each couch and inspect the image set for inhomogeneities resulting from the fabrication process (there should not be any).…”
Section: A Treatment Tabletopsmentioning
confidence: 99%
“…Because material inserted between the proton therapy system and the patient reduces proton penetration and scatters the beam, it is recommended that the effect of the treatment couch be considered in cases in which the beam passes through it. A further complication arises if the treatment couch differs from the couch used for TPS simulation 64 . Therefore, a set of physical and radiologic tests should be carried out to ensure the uniformity of the treatment couches to be used.…”
Section: Ancillary Devices and Materialsmentioning
confidence: 99%
See 1 more Smart Citation
“…Inserting a treatment couch top that mimics the physical dimensions and materials of the actual treatment couch top is important because the accuracy of the delivered proton beam range requires accurate knowledge of the materials through which the beam passes during the planning process. The digital couch used at our institution was described elsewhere [28] and a similar digital couch was reported for treatment planning at the proton facility in Korea [29]. …”
Section: Methodsmentioning
confidence: 99%
“…Proton radiation has totally different dosimetric characteristics from those of conventional radiation therapy [1]. X-ray radiation exhibits exponentially decaying energy deposition in tissue with increasing depth beyond a build-up region, whereas protons exhibit an increasing energy deposition with the penetration depth, with a maximum energy deposition, the Bragg peak and near the end of the proton beam range [2].…”
Section: Introductionmentioning
confidence: 99%