2006
DOI: 10.1002/aic.10963
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of CO2 absorber using an AMP solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
53
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 77 publications
(53 citation statements)
references
References 30 publications
0
53
0
Order By: Relevance
“…Fig. 7 shows the results for 15 wt% AMP in NMP or TEGDME, at 50 • C, and those reported in the literature for AMP in ethylene glycol (EG) (Zheng et al, 2013), and aqueous solutions of AMP (Arcis et al, 2008;Gabrielsen et al, 2006;Mehdizadeh et al, 2013). Zheng et al (2013) reported a correlation for calculating the heat of absorption for solutions of AMP and EG, as a function of temperature and CO 2 loading, that was derived from the solubility data determined in that work, using the Gibbs-Helmholtz equation.…”
Section: Tablementioning
confidence: 94%
See 2 more Smart Citations
“…Fig. 7 shows the results for 15 wt% AMP in NMP or TEGDME, at 50 • C, and those reported in the literature for AMP in ethylene glycol (EG) (Zheng et al, 2013), and aqueous solutions of AMP (Arcis et al, 2008;Gabrielsen et al, 2006;Mehdizadeh et al, 2013). Zheng et al (2013) reported a correlation for calculating the heat of absorption for solutions of AMP and EG, as a function of temperature and CO 2 loading, that was derived from the solubility data determined in that work, using the Gibbs-Helmholtz equation.…”
Section: Tablementioning
confidence: 94%
“…The data for CO2 absorption in aqueous solutions of 15 and 30 wt% AMP at 49.35 • C are from Arcis et al (2008), and the data for CO2 absorption in 25 wt% AMP at 40 • C are from Mehdizadeh et al (2013). The dashed line is calculated using the correlation between the heat of absorption and CO2 loading, in aqueous solutions of AMP at 50 • C, reported by Gabrielsen et al (2006).…”
Section: Tablementioning
confidence: 98%
See 1 more Smart Citation
“…Gabrielsen et al, 2006), one of them being a kinetically controlled and reversible reaction (11) and the remaining two instantaneous and reversible reactions ,…”
Section: Reaction Scheme Of the Co 2 -Amp Systemmentioning
confidence: 99%
“…Nowadays, the rate-based models are mostly used, being typically implemented in AspenTech AspenPlus (RATEFRAC or RateSep unit), Aspen Custom Modeller Kucka et al ., 2003), gPROMS , Mathworks Matlab (Gabrielsen et al ., 2006), FORTRAN (Thiele et al ., 2007), ProTreat or even CFD software (e.g. ANSYS CFX).…”
Section: Modelling Design and Simulationmentioning
confidence: 99%