Abstract:Building-integrated solar thermal systems (BIST) outperform building-added solar thermal systems (BAST) due to smaller heat losses at the back of the collector. BIST offer economic advantages, too. The insulation behind the collector can be used to reduce the heating demand of the building as well as to increase the solar thermal yield. Therefore, less material and labour are needed. Of course, the energy flux to the building interior needs to be considered. This energy flux depends in general on the operation… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.