2020
DOI: 10.1016/j.jelechem.2020.113996
|View full text |Cite
|
Sign up to set email alerts
|

Modification of a pencil graphite electrode with multiwalled carbon nanotubes capped gold nanoparticles for electrochemical determination of tramadol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 53 publications
(23 citation statements)
references
References 32 publications
0
23
0
Order By: Relevance
“…Prior to functionalization, the glassy carbon electrode (GCE) was buffed with alumina powder (0.03 μm) and then was ultrasonically cleaned by absolute ethyl alcohol and ultrapure water for 20 min. In order to capture the thiol-modified h-DNA via the Au–S bonds, two different gold nanospheres (GNSs) functional electrodes were prepared based on previous studies: 28 (1) MWCNTs–GNSs-coated GCE (MWCNTs–GNSs/GCE). Here, 2 mg of MWCNTs was dissolved in N,N -dimethylformamide and ultrasonically dispersed for 30 s at room temperature to form a uniform solution.…”
Section: Methodsmentioning
confidence: 99%
“…Prior to functionalization, the glassy carbon electrode (GCE) was buffed with alumina powder (0.03 μm) and then was ultrasonically cleaned by absolute ethyl alcohol and ultrapure water for 20 min. In order to capture the thiol-modified h-DNA via the Au–S bonds, two different gold nanospheres (GNSs) functional electrodes were prepared based on previous studies: 28 (1) MWCNTs–GNSs-coated GCE (MWCNTs–GNSs/GCE). Here, 2 mg of MWCNTs was dissolved in N,N -dimethylformamide and ultrasonically dispersed for 30 s at room temperature to form a uniform solution.…”
Section: Methodsmentioning
confidence: 99%
“…An araldite mixture (epoxy resin, 1:1) [16,41,[43][44][45], bentonite [38,39], or cyanoacrylate glue [40] was used to fix the graphite lead into the support. Other PGEs were obtained by covering a part of the graphite lead with nail polish [53] or with Teflon tape [20,[54][55][56][57][58][59][60][61][62][63][64][65] (Figure 1e), leaving a constant length and area of nacked pencil mine to act as an electroative surface. The electrical contact with the potentiostat is provided by a metallic (copper) wire wrapped arround the end of the mine, which is not exposed to the analyzed solution.…”
Section: Pge Manufacturing Proceduresmentioning
confidence: 99%
“…A bismuth film-plated PGE [104] and a porous copper microparticles modified PGE were fabricated by ex situ potentiostatic deposition [19] and then transferred to the analyte solution, which was voltametrically investigated (Table 3). Layers and nanoparticles of various other materials were also deposited on the PGE surface by applying a given potential for a certain time [61,[63][64][65]68,91,92,[105][106][107].…”
Section: Applications Of (Electro)chemically Modified Pges To the Vol...mentioning
confidence: 99%
See 1 more Smart Citation
“…Approximately 50% of consumed SMT remains unmetabolised in parent animals and may be excreted to water bodies [ 8 ]. Another investigated PPCP in this study is TRA, which is a painkiller and opioid analgesic [ 9 ]. It is not completely eliminated by wastewater treatment plants and usually discovered in effluents after treatment and in surface waters [ 10 ].…”
Section: Introductionmentioning
confidence: 99%