2022
DOI: 10.3390/en15207814
|View full text |Cite
|
Sign up to set email alerts
|

Modified Cascaded Controller Design Constructed on Fractional Operator ‘β’ to Mitigate Frequency Fluctuations for Sustainable Operation of Power Systems

Abstract: The demand for energy is increasing at an abrupt pace, which has highly strained the power system, especially with high share of power generation from renewable energy sources (RES). This increasing strain needs to be effectively managed for a continuous and smooth operation of the power system network. Generation and demand exhibit a strong correlation that directly creates an impact on the power system frequency. Fluctuations and disruptions in load frequency can manifest themselves as over-voltages and phys… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 33 publications
0
6
0
Order By: Relevance
“…The cascaded (FOPI-PDF) controller gains will be ascertained by minimizing the cost function (CF) using the DTBO algorithm. The integral of time weighted by the squared error (ITSE) [4,26] is chosen as the CF because it can reduce time settling and overwhelm high oscillations quickly [30]:…”
Section: Proposed Control Structure and Fitness Functionmentioning
confidence: 99%
“…The cascaded (FOPI-PDF) controller gains will be ascertained by minimizing the cost function (CF) using the DTBO algorithm. The integral of time weighted by the squared error (ITSE) [4,26] is chosen as the CF because it can reduce time settling and overwhelm high oscillations quickly [30]:…”
Section: Proposed Control Structure and Fitness Functionmentioning
confidence: 99%
“…By lowering greenhouse gas emissions, RES help to create a sustainable environment. The incorporation of RESs, primarily photovoltaic, wind power, small hydro, fuel cells and biomass has resulted in a major dynamic characteristic shift in power systems over the last decade because of their technical and economic importance [2,3].…”
Section: Introduction 11 Literature Reviewmentioning
confidence: 99%
“…This architecture aimed to effectively implement a system encompassing a diagnosis, warning, and instant failure response, with detailed descriptions provided [27]. An improved cascaded structure based on the proportional integral with a fractional operator coupled with the proportional derivative was proposed [28]. The controller (1 + PD) was modified by introducing the fractional properties that improved its tracking efficiency and mitigated the frequency fluctuations taking minimal time.…”
Section: Introductionmentioning
confidence: 99%
“…The modern power system keeps advancing towards a huge complex artificial system. The interactions between electrical elements can become highly complex, to the point where even a minor disturbance can initiate a chain reaction throughout the entire system, commonly referred to as cascading [22,28]. Additionally, the recovery scenarios should be prepared by considering the worst situations.…”
Section: Introductionmentioning
confidence: 99%