2018
DOI: 10.1049/iet-gtd.2018.0194
|View full text |Cite
|
Sign up to set email alerts
|

Moisture estimation for oil‐immersed bushing based on FDS method: field application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…Measurements were performed at six measurement temperatures: 293. 15 This had a positive impact on the accuracy of the determination of the activation energy of the direct and alternating current conductivity of the oil-impregnated pressboard.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Measurements were performed at six measurement temperatures: 293. 15 This had a positive impact on the accuracy of the determination of the activation energy of the direct and alternating current conductivity of the oil-impregnated pressboard.…”
Section: Methodsmentioning
confidence: 99%
“…To test the moisture content of power transformer insulation, diagnostic methods based on relaxation changes in the time domain using the recovery voltage method (RVM) [3][4][5][6] and polarization depolarization current (PDC) method [7][8][9][10] are used. In the frequency domain, however, the values of the loss factor tgδ and system capacity at low frequencies are determined using the frequency domain spectroscopy (FDS) method [11][12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the authors in Refs. [14,15] introduced a method, based on the FDS results, for assessing the OIP bushing's moisture level. Additionally, they have realised that the temperature can affect the values of tanδ.…”
Section: Introductionmentioning
confidence: 99%
“…What should be noted is that moisture can be produced during the thermal aging process of the internal insulation. Besides, due to the loose of nut, cracks in external insulation and poor sealing of oil pillow, the invasion of external moisture from the environment is the main way in field [15], [16]. For oil-immersed insulation paper, moisture is a harmful agent that catalyzes the thermal aging reactions and accelerates the aging process, which reduces the dielectric strength, decreases the partial-discharge inception voltage and increases the fault probability [17].…”
Section: Introductionmentioning
confidence: 99%