2004
DOI: 10.1007/s11090-004-2273-1
|View full text |Cite
|
Sign up to set email alerts
|

Molecular Beam Mass Spectrometry System for Characterization of Thermal Plasma Chemical Vapor Deposition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 18 publications
0
9
0
Order By: Relevance
“…TIMS can also be used for the detection of metastable particles such as N 2 (A 3 + u ) [61] or O 2 (a 1 g ) [62]. Many reports of TIMS of radicals can be found in the literature for fluorocarbon [33,63], oxygen [21,64], chlorine [65], silane [66][67][68][69] or hydrocarbon [34, 35, 66-68, 70, 71] plasmas.…”
Section: Measurement Of Short-lived Reactive Neutral Speciesmentioning
confidence: 99%
“…TIMS can also be used for the detection of metastable particles such as N 2 (A 3 + u ) [61] or O 2 (a 1 g ) [62]. Many reports of TIMS of radicals can be found in the literature for fluorocarbon [33,63], oxygen [21,64], chlorine [65], silane [66][67][68][69] or hydrocarbon [34, 35, 66-68, 70, 71] plasmas.…”
Section: Measurement Of Short-lived Reactive Neutral Speciesmentioning
confidence: 99%
“…The integrated energy enables us to plot and compare concentration profiles for ions of similar masses. However, relative ion concentration profile can only be obtained after the overall mass discrimination of the system is measured 14 . The overall mass discrimination of the present MBMS system with quadrupole mass spectrometer depends on two factors, transmission efficiency and enrichment factor 14 .…”
Section: Resultsmentioning
confidence: 99%
“…However, relative ion concentration profile can only be obtained after the overall mass discrimination of the system is measured 14 . The overall mass discrimination of the present MBMS system with quadrupole mass spectrometer depends on two factors, transmission efficiency and enrichment factor 14 . The transmission efficiency of the quadrupole detector varies with mass such that quadrupoles typically have higher transmission efficiency for lower mass ions.…”
Section: Resultsmentioning
confidence: 99%
“…In MBMS, the plasma composition is measured by sampling a gas through a small orifice into a differentially pumped vacuum system ͑usually with two or three pumping stages͒ containing a mass spectrometer ͑MS͒. [1][2][3][4][5] The sampling orifice is in line of sight with the ionizer of the MS and therefore even reactive species with high surface reactivity can be detected. MBMS provides, when properly designed and calibrated, absolute densities; a very important information for the identification of growth precursors.…”
Section: Molecular Beam Sampling System With Very High Beam-to-backgrmentioning
confidence: 99%