2019
DOI: 10.1021/acs.cgd.9b00886
|View full text |Cite
|
Sign up to set email alerts
|

Molecular Simulation Approaches for the Prediction of Unknown Crystal Structures and Solubilities of (R)- and (R,S)-Crizotinib in Organic Solvents

Abstract: In this work, the solubilities of (R)- and (R,S)-crizotinib in six solvents including methanol, ethanol, 1-propanol, 1-butanol, ethyl acetate, and n-hexane were first measured by a static method in the temperature range from 273.15 to 323.15 K at atmospheric pressure. Then, molecular simulations were performed to predict the crystal structures of (R)-crizotinib and (R,S)-crizotinib from their powder X-ray diffractograms and the solubilities in the above organic solvents using the Gibbs free energy calculation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 24 publications
(14 citation statements)
references
References 61 publications
0
14
0
Order By: Relevance
“…The samples were scanned from 5 to 50°(2θ) at a scanning rate of 0.02°s −1 . 39 FTIR spectra of (D)-, (L)-, and (D,L)-penicillamine were acquired using a Spectrum Two Fourier-transform infrared spectrometer (PerkinElmer, Norwalk, CT). Ground KBr powder was used as the background in the measurements.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The samples were scanned from 5 to 50°(2θ) at a scanning rate of 0.02°s −1 . 39 FTIR spectra of (D)-, (L)-, and (D,L)-penicillamine were acquired using a Spectrum Two Fourier-transform infrared spectrometer (PerkinElmer, Norwalk, CT). Ground KBr powder was used as the background in the measurements.…”
Section: Methodsmentioning
confidence: 99%
“…PXRD was performed using an X’Pert Pro diffractometer (PANalytical, Almelo, The Netherlands) with Cu Kα radiation (λ = 1.5418 Å) at 40 mA and 40 kV. The samples were scanned from 5 to 50° (2θ) at a scanning rate of 0.02° s –1 …”
Section: Experimental Sectionmentioning
confidence: 99%
“… 38 PXRD was operated on a TD-3700 diffractometer with Cu Kα radiation (Tongda Instruments, Dandong, China). The step length from 3 to 80° was 0.05°, and the time per step was 5 s. 39 The thermal analyses by DSC and TGA were conducted on an HSC-4 differential scanning calorimeter (Henjiu Experimental Equipment, Bejing, China) and a WRT-12 thermogravimetric analyzer (Beiguang Hongyuan Instruments, Beijing, China), respectively. The heating rate was 5.0 K per minute.…”
Section: Experimental Sectionmentioning
confidence: 99%
“…The solubilities of three species of Asp in water from 288.15 to 323.15 K were determined, referring to ref ( 39 ). Each solubility measurement was performed using 50 mL of double-jacketed crystallizers.…”
Section: Experimental Sectionmentioning
confidence: 99%
“…For example, a geometry-based generative model can generate graphs within the predefined geometric rules but can-not generalize to other geometric properties. However, in many domains, the network properties and generation principles are largely unknown, such as those for explaining the thermal probability (Tabero et al, 2018) and solubilities (Fan et al, 2019a) of materials. Here the lack of predefined principles leads to the incapability of existing methods to model periodic graphs.…”
Section: Introductionmentioning
confidence: 99%