2022
DOI: 10.1016/j.bios.2022.114203
|View full text |Cite
|
Sign up to set email alerts
|

Molecularly imprinted polymer-based extended-gate field-effect transistor (EG-FET) chemosensor for selective determination of matrix metalloproteinase-1 (MMP-1) protein

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
23
0
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 34 publications
(25 citation statements)
references
References 29 publications
1
23
0
1
Order By: Relevance
“…Molecularly imprinted polymers (MIPs) have been synthesized for the recognition of target molecules, and have been widely used in bioseparations [ 8 , 9 , 10 ], biosensing [ 8 , 11 , 12 , 13 , 14 ], and medicines [ 15 , 16 ]. Zhang’s group developed epitope-imprinted nanoparticles for the recognition of oxytocin [ 17 ], bovine serum albumin [ 18 , 19 ], tyrosine phosphopeptide [ 20 ], human serum albumin [ 21 ], and cytochrome c [ 22 , 23 , 24 ].…”
Section: Introductionmentioning
confidence: 99%
“…Molecularly imprinted polymers (MIPs) have been synthesized for the recognition of target molecules, and have been widely used in bioseparations [ 8 , 9 , 10 ], biosensing [ 8 , 11 , 12 , 13 , 14 ], and medicines [ 15 , 16 ]. Zhang’s group developed epitope-imprinted nanoparticles for the recognition of oxytocin [ 17 ], bovine serum albumin [ 18 , 19 ], tyrosine phosphopeptide [ 20 ], human serum albumin [ 21 ], and cytochrome c [ 22 , 23 , 24 ].…”
Section: Introductionmentioning
confidence: 99%
“…That decreased the differential pulse voltammetry (DPV) peak current, resulting in a sensor signal that varied linearly with the protein concentration of 1 to 200 ng/mL, with a limit of detection of 0.3 ng/mL [ 23 ]. Our previous work demonstrated the optimized molar ratio of functional monomers to templates with the linear dynamic concentration range of 50–500 nM [ 24 ].…”
Section: Introductionmentioning
confidence: 99%
“…Such a standard MOSFET can also be used in liquid-sample FET-based (bio)sensing in an extended-gate configuration (EGFET) [8][9][10] (see the scheme in Fig. 1B).…”
Section: Introductionmentioning
confidence: 99%
“…Here, a MOSFET acts as a transducer with the sensing surface attached to its gate (typically either a glass pH electrode used herein or e.g. a gold electrode with thiol chemistry coupled specific receptors [8][9][10] ) forming an extended gate, which is submerged in the liquid solution along with a reference electrode (e.g. Ag/AgCl).…”
Section: Introductionmentioning
confidence: 99%