2007
DOI: 10.1016/j.talanta.2006.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Molecularly imprinted polymer-based potentiometric sensor for degradation product of chemical warfare agentsPart I. Methylphosphonic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
28
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 62 publications
(29 citation statements)
references
References 17 publications
1
28
0
Order By: Relevance
“…The plasticizer NPOE having a high dielectric constant of 24.0 has given better response characteristics than that of DOP ( ε = 5.0), BEHS ( ε = 4.0) and TEHP ( ε = 4.8). This is in agreement with earlier reports [20,21]. It was also observed that the imprinted membranes casted without plasticizer were not suitable for use as recognition membranes as they are brittle.…”
Section: Influence Of Plasticizersupporting
confidence: 93%
See 3 more Smart Citations
“…The plasticizer NPOE having a high dielectric constant of 24.0 has given better response characteristics than that of DOP ( ε = 5.0), BEHS ( ε = 4.0) and TEHP ( ε = 4.8). This is in agreement with earlier reports [20,21]. It was also observed that the imprinted membranes casted without plasticizer were not suitable for use as recognition membranes as they are brittle.…”
Section: Influence Of Plasticizersupporting
confidence: 93%
“…The recovery studies of DCP from ground and river waters indicated the possibility of using the sensor investigated in the present work for nature water samples. The developed technology found to be a effective analytical tool as it requires simple sample preparation procedures and does not require large instrumentation as it is a miniature device that responds to a particular analyte in a selective way and can be effectively used for the determination of pollutants in the environmental and biological samples [20,23]. Further studies are in progress to integrate other transducers with MIP materials for a chosen template.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Despite the relatively simple transduction of the potentiometric signal, only limited reports on the design of the potentiometric sensors have been based on the molecular imprinting technology. These reports describe the dispersion of the MIP particles in the plasticizer and their embedment in a polyvinylchloride (PVC) matrix, [18][19][20][21] the formation of a glassy membrane, 22 the template assembly on the polar surface of the indium tin oxide (ITO) glass plate 23,24 and the deposition of an MIP polymeric film on the gate surface of an ion-sensitive field-effect transistor. 25,26 The prescription of new antidepressant drugs has increased dramatically in the last few years.…”
Section: Introductionmentioning
confidence: 99%