2007
DOI: 10.1016/j.snb.2006.07.022
|View full text |Cite
|
Sign up to set email alerts
|

Molecularly imprinted polymer (biomimetic) based potentiometric sensor for atrazine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
44
0
1

Year Published

2008
2008
2022
2022

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 84 publications
(45 citation statements)
references
References 13 publications
0
44
0
1
Order By: Relevance
“…18,39 To evaluate the response of MIPs to the specific binding of sertraline hydrochloride, the amount of the imprinted polymer was increased with a fixed amount of PVC. The results in Table 1 show that the membrane having the weight of PVC to MIP particles in the ratio 1:0.5 (10.3 wt.% of MIP) gave the best performance (membrane No.…”
Section: Effect Of Mip Particles To Pvc Ratiomentioning
confidence: 99%
See 1 more Smart Citation
“…18,39 To evaluate the response of MIPs to the specific binding of sertraline hydrochloride, the amount of the imprinted polymer was increased with a fixed amount of PVC. The results in Table 1 show that the membrane having the weight of PVC to MIP particles in the ratio 1:0.5 (10.3 wt.% of MIP) gave the best performance (membrane No.…”
Section: Effect Of Mip Particles To Pvc Ratiomentioning
confidence: 99%
“…Despite the relatively simple transduction of the potentiometric signal, only limited reports on the design of the potentiometric sensors have been based on the molecular imprinting technology. These reports describe the dispersion of the MIP particles in the plasticizer and their embedment in a polyvinylchloride (PVC) matrix, [18][19][20][21] the formation of a glassy membrane, 22 the template assembly on the polar surface of the indium tin oxide (ITO) glass plate 23,24 and the deposition of an MIP polymeric film on the gate surface of an ion-sensitive field-effect transistor. 25,26 The prescription of new antidepressant drugs has increased dramatically in the last few years.…”
Section: Introductionmentioning
confidence: 99%
“…All of them were based on the use of very thin membranes or films (Zhou et al, 2004). Prasad et al (2007) report a new strategy to construct a potentiometric biomimetic sensor for direct, rapid and highly selective detection of atrazine. The stability, reusability and dynamic response time are analogous to conventional chemical sensors.…”
Section: Transducersmentioning
confidence: 99%
“…Finally, MIP for atrazine was prepared according to Prasad et al [24] as follows: atrazine (1 mmol) was dissolved in toluene (5 mL) in a dried 30 mL test tube and the functional monomer (MAA, 4 mmol), EGDMA (20 mmol) and AIBN (50 mg) were added and the components were gently mixed. Then the reaction mixture was…”
Section: Preparation Of Molecularly Imprinted Polymers (Mips)mentioning
confidence: 99%