2022
DOI: 10.1007/s00604-022-05470-8
|View full text |Cite
|
Sign up to set email alerts
|

Molecularly imprinted polymer specific to creatinine complex with copper(II) ions for voltammetric determination of creatinine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 46 publications
1
3
0
Order By: Relevance
“…The sensor was tested with similar compounds of creatinine (e.g., caffeine, uric acid, and melamine) and showed selectivity to creatinine. A good agreement was obtained with the results from human plasma samples spiked with creatinine evaluated with the sensor and with HPLC [90]. Furthermore, Sergeyeva et al fabricated a colorimetric MIP sensor for the detection of creatinine by the immersion of a poly(vinylidene difluoride) (PVDF) membrane (pores of 0.22 µm) into a mixture of creatinine (template), itaconic acid (IA, monomer), MAA (monomer), 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPSA, monomer), and MBA (crosslinker) subjected to UV (365 nm) for 10 min.…”
Section: Creatininesupporting
confidence: 74%
“…The sensor was tested with similar compounds of creatinine (e.g., caffeine, uric acid, and melamine) and showed selectivity to creatinine. A good agreement was obtained with the results from human plasma samples spiked with creatinine evaluated with the sensor and with HPLC [90]. Furthermore, Sergeyeva et al fabricated a colorimetric MIP sensor for the detection of creatinine by the immersion of a poly(vinylidene difluoride) (PVDF) membrane (pores of 0.22 µm) into a mixture of creatinine (template), itaconic acid (IA, monomer), MAA (monomer), 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPSA, monomer), and MBA (crosslinker) subjected to UV (365 nm) for 10 min.…”
Section: Creatininesupporting
confidence: 74%
“…Moreover, Cu 2+ ions have a high charge density to carry four creatinine molecules via high coordination number through endocyclic nitrogen atoms of creatinine molecules. 43 However, no significant change in reduction peak current was ascribed to the fact that Cu( i ) has less affinity for CRE molecules because Cu( i ) prefers complexes with low coordination number, which takes place through many structural and stereochemical changes of the complexes. 44 As a result, in reverse scan there is no complex formation taking place with Cu + .Cu (0) → Cu 2+ Cu 2+ + (CRE) → Cu-CRE complex (soluble)…”
Section: Resultsmentioning
confidence: 99%
“…Molecularly imprinted polymer (MIP) is a polymeric matrix with cavities, which simulates the interaction between antibodyantigen to bind with the specific biomarkers. [19,20] MIP-based biosensors have been developed over recent years for the ultrasensitive detection of various biomarkers, [21,22] including creatinine, urea, and HSA, [23][24][25] with excellent sensitivity and selectivity for direct measurements in clinical samples. However, the intrinsic disadvantages of the traditional MIP biosensors still re-main, mainly with binding sites heterogeneity and slow diffusion mass transfer of analytes to the imprinted sites affecting their overall performance.…”
Section: Introductionmentioning
confidence: 99%