1996
DOI: 10.1016/0304-3894(95)00159-x
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring and modeling of PCB dry deposition in urban area

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
23
0
5

Year Published

2006
2006
2015
2015

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 44 publications
(31 citation statements)
references
References 22 publications
3
23
0
5
Order By: Relevance
“…The average dry deposition fluxes of PCDD/Fs determined from this study were approximately 2 times lower than those observed at urban area of Japan (36-51 pg I-TEQ/m 2 -day) (Ogura et al, 2001), but similar findings were determined at urban areas of Taiwan (Shih et al, 2006;Wu et al, 2009;Huang et al, 2011), Korea (Moon et al, 2005), and industrial areas of Italy (Guerzoni et al, 2004). As for deposition fluxes of PCBs, values obtained in this study were two to three orders of magnitude lower than the previously reported values measured in suburban site of Turkey (2.1-163 ng/m 2 -day), urban and rural areas of USA, and Tainan, Taiwan (Lee et al, 1996b;Franz et al, 1998;Tasdemir et al, 2004a;Tasdemir and Holsen, 2005;Cindoruk and Tasdemir, 2007) (Table 9). The difference can be attributed to variations in ambient concentrations, sampling techniques, sites, and durations.…”
Section: Dry Deposition Fluxes Of Pcdd/fs and Pcbssupporting
confidence: 83%
See 3 more Smart Citations
“…The average dry deposition fluxes of PCDD/Fs determined from this study were approximately 2 times lower than those observed at urban area of Japan (36-51 pg I-TEQ/m 2 -day) (Ogura et al, 2001), but similar findings were determined at urban areas of Taiwan (Shih et al, 2006;Wu et al, 2009;Huang et al, 2011), Korea (Moon et al, 2005), and industrial areas of Italy (Guerzoni et al, 2004). As for deposition fluxes of PCBs, values obtained in this study were two to three orders of magnitude lower than the previously reported values measured in suburban site of Turkey (2.1-163 ng/m 2 -day), urban and rural areas of USA, and Tainan, Taiwan (Lee et al, 1996b;Franz et al, 1998;Tasdemir et al, 2004a;Tasdemir and Holsen, 2005;Cindoruk and Tasdemir, 2007) (Table 9). The difference can be attributed to variations in ambient concentrations, sampling techniques, sites, and durations.…”
Section: Dry Deposition Fluxes Of Pcdd/fs and Pcbssupporting
confidence: 83%
“…The estimated dry deposition flux of PCDD/Fs was approximately 4 times the wet deposition. Lee et al (1996b) reported the modeled and measured dry deposition flux of PCBs in an urban site of Taiwan. It was found that all the modeled and measures dry deposition data were within 41% of difference, revealing a good prediction of the adopted models in the authors study.…”
Section: Polychlorinatedmentioning
confidence: 99%
See 2 more Smart Citations
“…By observing deposited particles, Tai, Lin, and Noll (1999) show that this effect is particularly true for urban locations where the coarse concentration of particles is high; however, the effect is also true for non-urban locations where the coarse concentration of particles is low. Similar results were obtained by Lee et al (1996) for PCB dry deposition in an urban area.…”
Section: Urban Deposition Modelssupporting
confidence: 88%