2015
DOI: 10.1117/1.jbo.20.10.105002
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring breast tumor progression by photoacoustic measurements: a xenograft mice model study

Abstract: The current study reports the photoacoustic spectroscopy-based assessment of breast tumor progression in a nude mice xenograft model. The tumor was induced through subcutaneous injection of MCF-7 cells in female nude mice and was monitored for 20 days until the tumor volume reached 1000  mm3. The tumor tissues were extracted at three different time points (days 10, 15, and 20) after tumor inoculation and subjected to photoacoustic spectral recordings in time domain ex vivo at 281 nm pulsed laser excitations. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
21
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(22 citation statements)
references
References 59 publications
1
21
0
Order By: Relevance
“…The animals were regularly checked for tumor development, and the tumor progression was measured for length and breadth using a digital Vernier caliper. The tumor volume kinetics was calculated using the formula mentioned below [ 19 ]. Based on the allowed tumor volume limit after MCF 7 cells injection, the entire tumor growth period was divided into 4 assessment time points (day 5, 10, 15, and 20) and conducted the study considering day 0 as control.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The animals were regularly checked for tumor development, and the tumor progression was measured for length and breadth using a digital Vernier caliper. The tumor volume kinetics was calculated using the formula mentioned below [ 19 ]. Based on the allowed tumor volume limit after MCF 7 cells injection, the entire tumor growth period was divided into 4 assessment time points (day 5, 10, 15, and 20) and conducted the study considering day 0 as control.…”
Section: Methodsmentioning
confidence: 99%
“…In recent times, there has been tremendous progress achieved in the instrumentation and imaging applications by the technique [ 18 ]. The photoacoustic spectroscopy’s ability to detect biochemical alterations upon the onset of breast tumor development has been demonstrated [ 19 ]. In combination with machine learning algorithms, photoacoustic spectroscopy has shown tremendous improvement in the classification of abnormal tissues from healthy, signifying its diagnostic capability and possible alternative to currently available tools for disease diagnosis [ 20 ].…”
Section: Introductionmentioning
confidence: 99%
“…34 Additionally, no studies have reported protein conformational changes through photoacoustic (PA) spectroscopy studies. 35,36 In most analytical methods, including photoacoustic spectroscopy, the spectral patterns are influenced by the background noises that arise from the instrumentation and the surroundings, affecting the overall signal quality. Further, when the signal is weak, the background noise dominates over the actual signal.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Rodrigues et al monitored the development of breast tumors in nude mice by utilizing PAS combined with support vector machine analysis [ 72 ]. Priya et al reported a method using wavelet principal component analysis-based logistic regression analysis to assess the tumor growth in mice [ 73 ]. Deng et al reviewed that PA imaging combined with deep learning can play an important role in cancer diagnosis and treatment [ 74 ].…”
Section: Non-invasive Monitoring Methods Based On Photoacoustic Spect...mentioning
confidence: 99%