Abstract: Experiments were carried out to monitor the evolution of the deposition of fine particles in trickle-bed reactors during the flow of nonpolar hydrocarbon oil-like liquid suspensions using electrical capacitance tomography (ECT) imaging. The accuracy of the ECT rendition was validated in the pristine (i.e., deposit-free) bed state by comparing the liquid holdup measurements from ECT with the liquid holdup from residence time distribution (RTD) measurements. The pulse-flow characteristics (pulse velocity and fre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0
1

Year Published

2010
2010
2016
2016

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 39 publications
(36 citation statements)
references
References 29 publications
0
35
0
1
Order By: Relevance
“…The Tikhonov algorithm was among the most successful reconstruction approaches. Moreover, application of ECT along with this reconstruction algorithm to determine liquid saturations in trickle-bed reactors was recently validated by Hamidipour et al 27 The same procedure was therefore used in this study to generate normalized permittivity maps from the measured capacitance data.…”
Section: Experimental Setup and Operating Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Tikhonov algorithm was among the most successful reconstruction approaches. Moreover, application of ECT along with this reconstruction algorithm to determine liquid saturations in trickle-bed reactors was recently validated by Hamidipour et al 27 The same procedure was therefore used in this study to generate normalized permittivity maps from the measured capacitance data.…”
Section: Experimental Setup and Operating Conditionsmentioning
confidence: 99%
“…The dominant pulse frequency was extracted from the estimated averaged power spectral densities of the liquid saturation data assembled into [40 packets of 2048 data points each. 27 For all conditions, pulse flow history was recorded by ECT for 30 min at 50 Hz for straight and inclined configurations alike. Time series of liquid saturation which contained more than 2000 pulses were analyzed.…”
Section: Pulse Flow Characteristicsmentioning
confidence: 99%
“…For clean conditions, the ECT sensor was calibrated between drained prewetted (as 0%) and flooded (as 100%) bed to provide liquid saturations. 25 Figures 8b-d illustrate these patterns corresponding to the previous experiments, i.e., no ECI injection, injection each 60 min, and each 30 min, respectively. For the same operating conditions, slightly different liquid patterns could arise from one bed filling to another depending on the microscopic structure of the bed and the forming flow paths.…”
Section: Ect Imaging Of Deposition Morphology Dynamics In On-off Modumentioning
confidence: 71%
“…3 mm over the column cross-section. 25 Moreover, the qualitative information unveiled about the structure of deposition under two-phase flow filtration conditions proved extremely rich and useful. 25 …”