Monitoring myoglobin by capillary zone electrophoresis with end-column amperometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
1

Year Published

2000
2000
2003
2003

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 25 publications
0
9
0
1
Order By: Relevance
“…In addition to UV, LIF, and MS detection, some other less common and novel detection methods have been explored, such as amperometric detection of myoglobin in human urine [84]. The use of chemiluminescence detection for CIEF has been demonstrated with a fiberoptic based detection cell [85], yielding a LOD in the nM range and a linear range of two orders of magnitude.…”
Section: Other Detection Methodsmentioning
confidence: 99%
“…In addition to UV, LIF, and MS detection, some other less common and novel detection methods have been explored, such as amperometric detection of myoglobin in human urine [84]. The use of chemiluminescence detection for CIEF has been demonstrated with a fiberoptic based detection cell [85], yielding a LOD in the nM range and a linear range of two orders of magnitude.…”
Section: Other Detection Methodsmentioning
confidence: 99%
“…Sistemas mais sofisticados envolvendo a remoção 40,52,157 , enzimas e proteínas [160][161][162] , co-fatores 163 , nucleotídeos e similares [164][165][166] , ácidos policarboxílicos 167 , hormônios 168 , bem como outros metabólitos, como ácido úrico 169 [197][198][199][200][201] . A ED também é bastante apropriada em separações eletroforéticas em meio não-aquoso (NACE), uma vez que a maioria dos solventes utilizados absorve fortemente na região do UV, o que dificulta as medidas fotométricas.…”
Section: Detecção Amperométrica (Ad)unclassified
“…Peptides or proteins containing electroactive amino acid residues such as tyrosine, cysteine, or tryptophan or other redox active functional groups have been detected at carbon fiber electrodes [47,50,51] and a cuprous oxide-modified carbon composite electrode [17]. Gold/mercury electrodes are often employed to detect glutathione [52,53]; the PQQ-mediated detection of glutathione has also been reported [18].…”
Section: Peptides and Proteinsmentioning
confidence: 99%
“…Cysteine [18], myoglobin [50], and acyclovir [83] have been determined in urine, and pyruvate has been detected in sweat [89]. CEEC was also used to quantify 8-hydroxydeoxyguanosine, an indicator of the degree of oxidative DNA damage [76].…”
Section: Determinations Of Drug Metabolites/ Biomarkers In Human Samplesmentioning
confidence: 99%