IEEE PES T&D 2010 2010
DOI: 10.1109/tdc.2010.5484207
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring of inter-area oscillations within the european interconnected network based on a wide area measuring system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
2
2
2

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 3 publications
0
7
0
Order By: Relevance
“…Therefore a very good measurement accuracy of 1 mHz is assured. Previous experiments with parallel measurement at two locations close to each other, but within different distribution grids show, that despite variable grid influences, the deviation ∆f * = f 1 * -f 2 * is below 1 mHz most of the time, see [5]. Furthermore, test series with a frequency synthesizer and comparisons with measurement data from Phasor Measurement Units (PMUs) on high voltage level verify these results.…”
Section: B Functionality Of the Measurement Systemmentioning
confidence: 61%
See 2 more Smart Citations
“…Therefore a very good measurement accuracy of 1 mHz is assured. Previous experiments with parallel measurement at two locations close to each other, but within different distribution grids show, that despite variable grid influences, the deviation ∆f * = f 1 * -f 2 * is below 1 mHz most of the time, see [5]. Furthermore, test series with a frequency synthesizer and comparisons with measurement data from Phasor Measurement Units (PMUs) on high voltage level verify these results.…”
Section: B Functionality Of the Measurement Systemmentioning
confidence: 61%
“…power grid frequency and voltage angle) are computed. For a detailed description of the measuring principle the reader is referred to [5]. Fig.…”
Section: B Functionality Of the Measurement Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Several studies have been carried out in the past using modal analysis and time-domain simulations to assess the nature of oscillation patterns in the ENTSO-E system [42][43][44][45][46][47][48]. With the help of the evolving technology of wide-area measurement system (WAMS) which has been installed in different countries, it has become possible to record information about the profiles of the inter-area oscillations of interest [49,50].…”
Section: Inter-area Oscillationsmentioning
confidence: 99%
“…Data come from [35] and detailed insight of WAMS can be found in [36], [37]. Also, the same data are used for inter-area oscillations analysis in [37].…”
Section: A Wide-area Frequency Datamentioning
confidence: 99%