Monitoring Suhu pada Infant Warmer Menggunakan INCU Analyzer Berbasis Arduino

Abstract: <em>Temperature is the most important parameter in monitoring Infant Warmer medical equipment. In this study, temperature monitoring was carried out on the Lullaby GE Infant Warmer using INCU based on Arduino Uno. The temperature setting used was 34 ° C, 35 ° C, 36 ° C and 37 ° C with each setting repeated 3 times. The temperature sensor used in the INCU analyzer for T1 to T4 is DS18B20, while the T5 uses a DHT22 temperature sensor. At the Infant Warmer temperature, a low error value was obtained for all… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 2 publications
1
1
0
Order By: Relevance
“…This also happened in the previous study, the difference in temperature sensor measurements was only about 0.13-0.182°C with the largest error of the system reaching 0.517% [33] and other studies achieved an error rate of only 0.28% [25]. Then based on other research, the results obtained for the error value were also less than 0.5°C [34]- [36]. The error value obtained from the DS18B20 sensor measurement was about 1% [37] [38] or 0.3°C.…”
Section: Discussionsupporting
confidence: 69%
See 1 more Smart Citation
“…This also happened in the previous study, the difference in temperature sensor measurements was only about 0.13-0.182°C with the largest error of the system reaching 0.517% [33] and other studies achieved an error rate of only 0.28% [25]. Then based on other research, the results obtained for the error value were also less than 0.5°C [34]- [36]. The error value obtained from the DS18B20 sensor measurement was about 1% [37] [38] or 0.3°C.…”
Section: Discussionsupporting
confidence: 69%
“…The error value obtained from the DS18B20 sensor measurement was about 1% [37] [38] or 0.3°C. The previous research also stated the results of the error value which obtained an error value of around 0.15 -0.29°C [39], 1.02% [21], 0.06% [16], 0.37% [36], and 2.18% [23]. These studies, in measuring temperature, calibrate with the same Incubator Analyzer tool used in this study.…”
Section: Discussionmentioning
confidence: 55%
“…Dalam kehidupan sehari-hari masyarakat untuk mengukur suhu cenderung menggunakan indra peraba. Tetapi dengan adanya perkembangan teknologi maka diciptakanlah termometer untuk mengukur suhu dengan valid [3].…”
Section: A Suhuunclassified