Background and objectives Very recently, Fresenius Kabi, improved the software (autoMNC lymphocytes, SW 04.03.08) for mononuclear cells (MNCs) collection with the aim to ameliorate the quality of harvest, employing the automated autoMNC lymphocytes software SW 04.03.09. Herein, we report the results of an observational study evaluating the feasibility of MNCs collection in patients undergoing extracorporeal photopheresis (ECP) at our centre, using the new COM.TEC software 04.03.08c for MNC collection, afterwards integrated in the software 04.03.09, available on the market since November 2018.Materials and methods Thirty adult patients (21 males and 9 females) with GvHD, Chronic Lung Allograft Dysfunction or renal rejection, were consecutively enrolled to undergo 1 ECP procedure by the offline technique, according to our internal protocol, processing 1Á5 blood volumes. Feasibility of collection was defined as: Hct in collection bag ≤5%, MNCs purity (percentage of MNCs/bag) ≥80%, MNCs collection efficiency (CE2) ≥60%, patient's platelet depletion ≤50%.Results Thirty ECP procedures were evaluated. Feasibility (defined by the four parameters previously described) of MNCs collection was observed in 1 out of the 30 harvests analysed. Median Hct in the product was 3Á45% (IQR: 2Á6-5Á0), and median MNCs purity was 97Á2% (IQR 89Á1-98Á6). Median CE2 for MNCs was 21Á4% (IQR: 11Á9-41Á2), and median patient's platelet depletion was 36Á2% (IQR 21Á9-51Á4).
ConclusionThe autoMNC lymphocytes software SW 04.03.08c for MNCs collection in ECP setting demonstrated to collect a good quality product in terms of purity and RBC contamination even if the collection efficiency and platelet contamination must be improved.