2014
DOI: 10.1002/pi.4747
|View full text |Cite
|
Sign up to set email alerts
|

Morphology and structure changes of aromatic copolysulfonamide fibers heat‐drawn at various temperatures

Abstract: The mechanical properties of copolysulfonamide (co‐PSA) fibers did not improve in spite of a substantial improvement in structural perfection at higher drawing temperature.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7

Relationship

6
1

Authors

Journals

citations
Cited by 22 publications
(24 citation statements)
references
References 25 publications
0
24
0
Order By: Relevance
“…According to eq , the radiuses of microvoids with circles cross section in the prepared fibers are calculated and the results are listed in Table . It demonstrates that the size of microvoids in the cross‐section of the prepared PI fibers exhibit multiorder characters . From Table , the incorporation of DABA monomers leads to a significant decrease in the radius of microvoids before the molar ratio of BIA/DABA reaches 5:5, and PI‐2 has the smallest microvoids, with 14.8, 35.3, and 65.8 Å, implying that homogeneous structure could provide co‐PI fibers more excellent performance.…”
Section: Resultsmentioning
confidence: 84%
“…According to eq , the radiuses of microvoids with circles cross section in the prepared fibers are calculated and the results are listed in Table . It demonstrates that the size of microvoids in the cross‐section of the prepared PI fibers exhibit multiorder characters . From Table , the incorporation of DABA monomers leads to a significant decrease in the radius of microvoids before the molar ratio of BIA/DABA reaches 5:5, and PI‐2 has the smallest microvoids, with 14.8, 35.3, and 65.8 Å, implying that homogeneous structure could provide co‐PI fibers more excellent performance.…”
Section: Resultsmentioning
confidence: 84%
“…The analysis for the microstructural changes of the thermal‐oxidative aging co ‐PSA fibers at large scale was done by SAXS as shown in Figure . According to previous studies, the equatorial streak of small‐angle diffuse scattering for heat‐drawn co ‐PSA fibers is generally attributed to the presence of fibrils elongated along the fiber axis. Therefore, the average length and misorientation angle Bϕ of fibril can be determined by the method of Ruland, as shown in Figure .…”
Section: Resultsmentioning
confidence: 85%
“…The sample‐to‐detector distances for WAXS and SAXS were 236.49 mm and 1,790 mm, respectively. All data analysis (background correction, radial, and azimuthal integration) was carried out using the Xpolar software (Precision works NY) as reported in our previous paper …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The sample‐to‐detector distance was 114.3 mm calibrating with a LaB 6 standard. Data analysis (background correction, radial and azimuthal integration) was carried out using X‐polar software (Precision Works Inc., NY, USA) as reported previously . The analysis was based on the three‐phase model .…”
Section: Methodsmentioning
confidence: 99%