1994
DOI: 10.1364/josab.11.002046
|View full text |Cite
|
Sign up to set email alerts
|

Morphology-dependent resonances in a cylindrical dye microlaser: mode assignments, cavity Q values, and critical dye concentrations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
6
0

Year Published

1996
1996
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 22 publications
1
6
0
Order By: Relevance
“…15 In fact, these optical modes never reach the film/core interface, and therefore, are dubbed whispering gallery modes ͑WGM͒. 10,11 The light in this case is confined by total internal reflections at the film/air interface, and the mode intensity distribution is concentrated on the outer edge of the film. The WGM wavelengths are still given by Eq.…”
Section: ͓S0003-6951͑98͒00115-6͔mentioning
confidence: 99%
“…15 In fact, these optical modes never reach the film/core interface, and therefore, are dubbed whispering gallery modes ͑WGM͒. 10,11 The light in this case is confined by total internal reflections at the film/air interface, and the mode intensity distribution is concentrated on the outer edge of the film. The WGM wavelengths are still given by Eq.…”
Section: ͓S0003-6951͑98͒00115-6͔mentioning
confidence: 99%
“…Mechanisms besides absorption which degrade the total Q i.e, increase the net loss, may also cause the lasing spectra to shift toward the blue. 86,87 The spectra in Fig. 26 suggest that it may be possible to estimate droplet temperatures from measurements of lasing spectra.…”
Section: Temperature Determination From Absorption-induced Q-degradationmentioning
confidence: 99%
“…83 A temperaturedependent configurational change (octahedral to tetrahedral with increasing temperature) in the Co 24 " complexes in the presence of Cl~ ion gives rise to thermochromism. 84,86 Droplets (radii ~ 35 /jm) are made from the mixture of 85% iso-propanol and 15% water with 0.1 M C0CI26H2O. The metallic orifice assembly is wrapped with a heating tape.…”
Section: Temperature Determination From Absorption-induced Q-degradationmentioning
confidence: 99%
“…Interference modulation was observed from a layered microtube by Knight et al. . These microcavities provide superior two‐dimensional optical confinement with Q values in excess of 10 6 and bode well for low laser thresholds.…”
Section: Introduction To Tubular Microcavitiesmentioning
confidence: 95%
“…These microcavities provide superior two‐dimensional optical confinement with Q values in excess of 10 6 and bode well for low laser thresholds. The fused‐silica capillary tube is filled with a dye‐doped liquid having a high refractive index and this type of microcavity laser is called a core‐resonance capillary‐fiber WGMs laser . The hollow microstructure (microsphere) was suggested by Artemyev et al.…”
Section: Introduction To Tubular Microcavitiesmentioning
confidence: 99%