2021
DOI: 10.1016/j.jvir.2021.03.536
|View full text |Cite
|
Sign up to set email alerts
|

MR Imaging‒Guided Intervention: Evaluation of MR Conditional Biopsy and Ablation Needle Tip Artifacts at 3T Using a Balanced Fast Field Echo Sequence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…As such, a phantom that has been adapted to the target tissue in musculoskeletal interventions (muscle phantom) was selected, in contrast to previous studies, which generally employed a 3 T MRI scanner. 25 , 26 Singh et al 25 evaluated needle artifact diameters using an acrylic phantom modifying only two parameters: IA and read-out direction. Furthermore, in the present study, contrast medium application was also performed for experimental evaluation of the visibility of the target lesion and to emulate as far as possible the clinical routine, exemplarily imitating contrast-enhanced MR-guided punctures of joint structures in the case of capsulitis.…”
Section: Discussionmentioning
confidence: 99%
“…As such, a phantom that has been adapted to the target tissue in musculoskeletal interventions (muscle phantom) was selected, in contrast to previous studies, which generally employed a 3 T MRI scanner. 25 , 26 Singh et al 25 evaluated needle artifact diameters using an acrylic phantom modifying only two parameters: IA and read-out direction. Furthermore, in the present study, contrast medium application was also performed for experimental evaluation of the visibility of the target lesion and to emulate as far as possible the clinical routine, exemplarily imitating contrast-enhanced MR-guided punctures of joint structures in the case of capsulitis.…”
Section: Discussionmentioning
confidence: 99%
“…However, it is acknowledged that in 3D image-guided interventions, needle artifact volume may be a relevant additional parameter. Though, depending on the sequence acquisition, such an assessment may be not adequately feasible, and several recent studies were also conducted in 2D 34 , 35 . Nevertheless, artifact volume and therefore possible differences to our measurement method should be investigated in future studies.…”
Section: Discussionmentioning
confidence: 99%
“…In a high-field (1.2 T) open system, the apparent widths of the 16 and 18 G biopsy introducer needles made of chromium and nickel-titanium alloys are up to 14 and 11 mm, respectively, on the gradient echo image [5]. In a high-field (3.0 T) closed system, the apparent widths of the 18 G biopsy needles composed of nickel and chromium alloys on the gradient echo image are up to 17 mm [33].…”
Section: Needle Artifactsmentioning
confidence: 99%