Abstract: Key Points Methods that use an MSKCC single 10-color tube or EuroFlow two 8-color tubes provide similar sensitivity in the detection of MRD in multiple myeloma.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
71
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 91 publications
(71 citation statements)
references
References 17 publications
0
71
0
Order By: Relevance
“…With a sensitivity of 10 −5 for NGS, all four patients were MRD positive. This limitation with the sensitivity threshold has now been overcome, since high‐resolution MFC achieves sensitivity levels equivalent to NGS . The IMWG response criteria state different response categories, depending on the method employed for MRD assessment Still, it makes more sense to establish the quality of response for MRD according to the depth of response, instead of the technique employed.…”
Section: Discussionmentioning
confidence: 99%
“…With a sensitivity of 10 −5 for NGS, all four patients were MRD positive. This limitation with the sensitivity threshold has now been overcome, since high‐resolution MFC achieves sensitivity levels equivalent to NGS . The IMWG response criteria state different response categories, depending on the method employed for MRD assessment Still, it makes more sense to establish the quality of response for MRD according to the depth of response, instead of the technique employed.…”
Section: Discussionmentioning
confidence: 99%
“…Flow cytometry in expert hands (available in a small number of expert centers) can reach sensitivities similar to NGS; however, there is still lack of standardization across laboratories. Loss of cells during antibody staining and use of more than one tube increases the number of cells required to guarantee 10 −6 sensitivity (3 million for the MSKCC 10‐color single tube assay and 10 million for the EuroFlow 8‐color two‐tube assay).…”
Section: Technological Advancesmentioning
confidence: 99%
“…To address this concern, the EuroFlow™ consortium developed next‐generation flow (NGF), which consists of 2 standardized flow cytometry tubes with 8 antibodies each, analytical process, event acquisition and data analysis using proprietary software (Flores‐Montero et al ) (Table ). Recently, investigators from the Memorial Sloan Kettering Cancer Center (Roshal et al , ) developed a single tube, 10‐colour method with results comparable to EuroFlow™, although the EuroFlow™ method is able to run a higher number of cells and provides an intra‐assay confirmation with 2 tubes.…”
Section: Challengesmentioning
confidence: 99%