2008
DOI: 10.1016/j.media.2008.02.004
|View full text |Cite
|
Sign up to set email alerts
|

MRI denoising using Non-Local Means

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
377
0
10

Year Published

2012
2012
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 510 publications
(393 citation statements)
references
References 17 publications
6
377
0
10
Order By: Relevance
“…The asymmetry of the Rician distribution results in a non-constant intensity bias as it depends on the local SNR. To reduce such bias, some authors have proposed to remove the bias in the squared magnitude image (Wiest-Daesslé et al, 2008, Manjón et al, 2008.…”
Section: Adaptation To Rician Noisementioning
confidence: 99%
See 1 more Smart Citation
“…The asymmetry of the Rician distribution results in a non-constant intensity bias as it depends on the local SNR. To reduce such bias, some authors have proposed to remove the bias in the squared magnitude image (Wiest-Daesslé et al, 2008, Manjón et al, 2008.…”
Section: Adaptation To Rician Noisementioning
confidence: 99%
“…This method reduces the noise by exploiting the self-similarity of the image patterns by averaging similar image patterns. In MRI, early works using the NLM method are from Coupe et al (2008) and Manjón et al (2008). The bibliography related to this method is quite extensive (Tristan-Vega et al, 20012;Coupe et al, 2012;Manjón et al, 2009Manjón et al, , 2010Manjón et al, , 2012Wiest-Daesslé et al, 2008;He and Greenshields, 2009;Rajan et al 2012Rajan et al , 2014.…”
Section: Introductionmentioning
confidence: 99%
“…Regarding denoising, which is the other focus of this paper, groups in the DWI denoising community have first denoised DW data assuming a Gaussian noise on each separate DWI channel (Manjòn et al, 2008). These techniques were then extended to take into account the Rician noise nature of the DWI signal (Coupé et al, 2010;Descoteaux et al, 2008;Aja-Fernàndez et al, 2008;Tristán-Vega and Aja-Fernández, 2010;Aja-Fernández et al, 2011;Brion et al, 2011) and, recently, the non-central Chi-squared distribution in the case where parallel imaging is used Brion et al, 2011).…”
Section: Theorymentioning
confidence: 99%
“…A recent framework inspired by nonlocal means MRI denoising (Buades et al, 2005;Coupe et al, 2008;Manjon et al, 2008) has been introduced to achieve the label fusion segmentation task.…”
Section: Introductionmentioning
confidence: 99%