2007
DOI: 10.3109/10929080601169930
|View full text |Cite
|
Sign up to set email alerts
|

MRI image overlay: Application to arthrography needle insertion

Abstract: Magnetic Resonance Imaging (MRI) offers great potential for planning, guiding, monitoring and controlling interventions. MR arthrography (MRAr) is the imaging gold standard for assessing small ligament and fibrocartilage injury in joints. In contemporary practice, MRAr consists of two consecutive sessions: (1) an interventional session where a needle is driven to the joint space and MR contrast is injected under fluoroscopy or CT guidance; and (2) a diagnostic MRI imaging session to visualize the distribution … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
10
0
1

Year Published

2010
2010
2015
2015

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(11 citation statements)
references
References 35 publications
0
10
0
1
Order By: Relevance
“…Il n'y a actuellement pas de solution commerciale offrant une assistance peropératoire guidant le chirurgien à travers l'utilisation de cette modélisation. Les travaux de recherche dans ce domaine sont, soit concentrés sur la ponction des tumeurs hépatiques [7][8][9][10][11][12][13], soit fondés sur une utilisation peropératoire d'une échographie 2D sur le foie [14][15][16][17][18]. Les premières utilisent généralement une méthode de recalage rigide supposant ainsi que le patient resterait dans une position figée identique à la position de l'acquisition avant l'opération.…”
Section: ❚ Introductionunclassified
“…Il n'y a actuellement pas de solution commerciale offrant une assistance peropératoire guidant le chirurgien à travers l'utilisation de cette modélisation. Les travaux de recherche dans ce domaine sont, soit concentrés sur la ponction des tumeurs hépatiques [7][8][9][10][11][12][13], soit fondés sur une utilisation peropératoire d'une échographie 2D sur le foie [14][15][16][17][18]. Les premières utilisent généralement une méthode de recalage rigide supposant ainsi que le patient resterait dans une position figée identique à la position de l'acquisition avant l'opération.…”
Section: ❚ Introductionunclassified
“…Researchers have identified the perceptive advantage of integrating the visualization of medical imaging data such as US [1,10], CT [18,4] or MRI [7] into the field of view of the surgeon using AR technology. Different hardware interfaces have been used to enable such augmented views of the operation site, for example optical see-through head mounted displays (HMD) [16,3,22,11], video see-through HMDs [17,1], virtual windows [19,5] or endoscope cameras [6].…”
Section: Introductionmentioning
confidence: 99%
“…For example, a CT image of a patient overlaid with the patient and appearing at the location of the actual anatomy was proposed in [7]. Usually the location of the surgery tool is tracked and graphically drawn as a virtual tool and displays on the CT or other images based on the tracking to guide surgeons to operate [8] [9]. If the mapping does not align correctly with the patient and the surgical tool, the visualization could be dangerous.…”
Section: Introductionmentioning
confidence: 99%