2013
DOI: 10.1117/12.2053851
|View full text |Cite
|
Sign up to set email alerts
|

Mueller-matrices polarization selection of two-dimensional linear and circular birefringence images

Abstract: The optical model of polycrystalline networks of myometium is suggested. The results of investigating the interrelation between the values correlation (correlation area, asymmetry coefficient and autocorrelation function excess) and fractal (dispersion of logarithmic dependencies of power spectra) parameters are presented. They characterize the distributions Mueller marixes elements of myometrium histological sections. The criteria of differentiation of death coming reasons are determined.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
13
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
3
3
1

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…value is preferably defined by phase anisotropy mechanisms -linear and circular birefringences [7][8][9][10][11][12][13][14][15][16][17][18][19][20]. ) is possible with the help of spatial-frequency Fourier selection [12,13]. Our research is aimed at designing the experimental method of azimuthally stable Fourier's polarimetry and spatialfrequency selection of parameter distributions of linear and circular birefringence of the blood plasma donors films and patients with liver cirrhosis.…”
Section: Part 1 Theoretical Basis Of Muller-matrix Imagingmentioning
confidence: 99%
“…value is preferably defined by phase anisotropy mechanisms -linear and circular birefringences [7][8][9][10][11][12][13][14][15][16][17][18][19][20]. ) is possible with the help of spatial-frequency Fourier selection [12,13]. Our research is aimed at designing the experimental method of azimuthally stable Fourier's polarimetry and spatialfrequency selection of parameter distributions of linear and circular birefringence of the blood plasma donors films and patients with liver cirrhosis.…”
Section: Part 1 Theoretical Basis Of Muller-matrix Imagingmentioning
confidence: 99%
“…Solution of this task can be reached using Muellermatrix cartography with the so-called rotational invariants. It has been shown in the works [4][5][6] that azimuthally stable, independent of the sample rotation angle ( ) are the following matrix elements const is possible by using spatialfrequency Fourier selection [12,13]. Our research is aimed at designing the experimental method of azimuthally stable Fourier polarimetry and spatial-frequency selection of parameter distributions for linear and circular birefringence in the blood plasma donor films and patients with liver cirrhosis.…”
Section: Theoretical Basis Of Muller-matrix Imagingmentioning
confidence: 99%
“…However, for non-depolarizing biological layers 5,6,[14][15][16][17][18][19][20][21][22][23][24][25][26][27][28] more appropriate to apply the Jones-matrix formalism.…”
Section: Introductionmentioning
confidence: 99%