2013
DOI: 10.1007/s00340-013-5381-x
|View full text |Cite
|
Sign up to set email alerts
|

Multi-color ultrafast laser platform for nonlinear optical imaging based on independently tunable optical parametric oscillators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
11
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 37 publications
0
11
0
Order By: Relevance
“…Image stacks (Z-step size 0.7-1.2 m) were collected using either a Zeiss LSM510 confocal microscope or custom-built 2P microscope (Yang et al, 2013). Confocal microscopy was performed using a 20ϫ (0.75 numerical aperture) PLAN NEOFLOUR lens.…”
Section: Methodsmentioning
confidence: 99%
“…Image stacks (Z-step size 0.7-1.2 m) were collected using either a Zeiss LSM510 confocal microscope or custom-built 2P microscope (Yang et al, 2013). Confocal microscopy was performed using a 20ϫ (0.75 numerical aperture) PLAN NEOFLOUR lens.…”
Section: Methodsmentioning
confidence: 99%
“…Other details and characteristics of the set up are described in our most recent work. 20 Figure 2(a) demonstrates sensitivity and the attainable time resolution using the experimental arrangement. In addition, using theoretical algorithms and owing to the experiment's great sensitivity, we can retrieve the vibrational system's response function and Raman spectra for several vibrational modes.…”
mentioning
confidence: 99%
“…In our studies we employed three-color CARS geometry with widely tunable 110-150 fs pulses. 19,20 The experimental set up is schematically shown in Figure 1. The two pulses that are needed to coherently drive lattice vibrations within a sample's macroscopic volume are provided by synchronously pumped optical parametric oscillators (OPOs) running at 76 MHz.…”
mentioning
confidence: 99%
“…Four images were taken in varying locations throughout each collagen gel piece. The total depth of the collagen gel was measured using twophoton fluorescent microscopy (Yang et al, 2011(Yang et al, , 2013 by imaging the fluorescence to determine the top and bottom of the gel.…”
Section: Gel Compression Studiesmentioning
confidence: 99%
“…Collagen gels were washed well with PBS and coverslipped with 90% glycerol/10% PBS containing 0.1 M n-propyl gallate (Giloh and Sedat, 1982). Z-stack images of the collagen gel were generated by taking 1.5 µm steps through the total depth of the gel using two-photon fluorescent microscopy (Yang et al, 2011(Yang et al, , 2013.…”
Section: Focal Adhesion Immunostaining In Three-dimensional (3-d) Colmentioning
confidence: 99%