2018
DOI: 10.1016/j.talanta.2017.08.013
|View full text |Cite
|
Sign up to set email alerts
|

Multi-elemental Nd, Sm, Eu, Gd isotope ratio measurements by stop-flow isotachophoresis coupled to MC-ICPMS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
6
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 35 publications
2
6
0
Order By: Relevance
“…Comparing the different data treatment methods, better reproducibilities were obtained with the LRS method, particularly when the signal intensity was lower than 5 mV. This observation is in agreement with previous studies performed by hyphenating separative techniques and MC-ICPMS. , …”
Section: Resultssupporting
confidence: 91%
See 2 more Smart Citations
“…Comparing the different data treatment methods, better reproducibilities were obtained with the LRS method, particularly when the signal intensity was lower than 5 mV. This observation is in agreement with previous studies performed by hyphenating separative techniques and MC-ICPMS. , …”
Section: Resultssupporting
confidence: 91%
“…This observation is in agreement with previous studies performed by hyphenating separative techniques and MC-ICPMS. 20,27 The U/ 238 U and U/ 238 U isotope ratio values for IRMM and IRMM obtained with the LRS method were in agreement within uncertainty with the certified ratio value of the isotopic standard. For the IRMM 184 standard 236 U/ 238 U ratio was not evaluated considering the very low abundance of 236 U.…”
Section: Mass Bias Correction Approach and Validationsupporting
confidence: 59%
See 1 more Smart Citation
“…A multi-collector inductively coupled plasma mass spectrometer (MC-ICPMS) is an elemental analysis instrument with a plasma ion source which can be used for the determination of element content and isotope analyses of samples. Vio et al [42] revealed four lanthanide samples (Nd, Sm, Eu and Gd) that were isotopically characterized by MC-ICPMS. The isotope composition of heavy metals in pollutants can be used to determine the source; then, effective methods can be adopted to remove the pollutants.…”
Section: Characterization Of Graphene-based Nanocompositesmentioning
confidence: 99%
“…The level of fractionation was the same for both ITP (LE: 14 mM 2‐hydroxy‐2‐methylbutyric acid, NH 4 Ac, pH 4.5; TE: 15 mM HAc), and CZE (BGE = LE). The same detection method and electrolyte system were used later for multielemental isotope ratio measurements of several lanthanides (Nd, Sm, Eu, and Gd). Between measurements of the individual ITP zones, electromigration was stopped to allow change of the detector parameters and injection of standards using a dual inlet spray chamber.…”
Section: Analytical Applicationsmentioning
confidence: 99%