Multi-Frequency Impedance Myography: The PhaseX Effect

Abstract: Muscle contraction is often detected via EMG in prosthetics. However, signal disturbances due to electrode motions can lead to misinterpretations. Therefore, alternative measurement approaches are desired to increase the reliability of the results. In this work, a novel approach based on impedance myography is proposed. By means of an equivalent circuit of a muscle, its electrical characteristics during contractions are analyzed. In this analysis, a new biomedical marker named the PhaseX Effect is described. T… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 28 publications
1
13
0
Order By: Relevance
“…Furthermore, a noticeable phase shift and increase of the phase peak also occurs in the phase spectrum while contracting the muscle. These results are consistent with previous demonstrations of EIM during muscle contractions employing high-accuracy bio-Z spectroscopy equipment [11].…”
Section: Experimental Verification Of Eimsupporting
confidence: 93%
See 2 more Smart Citations
“…Furthermore, a noticeable phase shift and increase of the phase peak also occurs in the phase spectrum while contracting the muscle. These results are consistent with previous demonstrations of EIM during muscle contractions employing high-accuracy bio-Z spectroscopy equipment [11].…”
Section: Experimental Verification Of Eimsupporting
confidence: 93%
“…1: Illustration of EIM measurement. of muscle contractions [10], [11] and has been proposed as a biomarker for NMDs, such as amyotrophic lateral sclerosis and duschenne muscle dystrophy [12], [13].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Impedance measurement systems have been developed for a variety of applications, including material characterization with inductive sensors [ 2 ], chemical parameters investigation [ 3 ], and characterization of biological tissues [ 4 , 5 ]. Impedance spectroscopy can be applied to monitor human activity [ 6 ], diagnose muscles [ 7 ], detect and characterize cancer [ 8 ], and monitor human health on a daily basis [ 9 ]. In this case, it is called bioelectrical impedance spectroscopy (BIS) [ 5 ], which is the main focus of this paper.…”
Section: Introductionmentioning
confidence: 99%
“…In the same direction, based on the IQ demodulation technique, Hernánder et al proposed a completed BIS device for body composition estimation with a sophisticated calibration method for better measurement accuracy [ 17 ]. From another perspective, Kusche et al evaluate the potential of BIS measurement for hand gestures recognition based on novel extracted features [ 6 ].…”
Section: Introductionmentioning
confidence: 99%