Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF)

Abstract: Aims Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the ‘real world’ performance of the only approved PFA catheter, including acute effectiveness and safety—in particular, rare oesophageal effects and other unforeseen PFA-related complications. Meth… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

19
206
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 214 publications
(226 citation statements)
references
References 28 publications
19
206
1
Order By: Relevance
“…In our study, we were able to create and block all anterior, roof and mitral isthmus lines with PFA. In the recently published Manifest PF survey of 24 European centers, roof lines and mitral isthmus lines were frequently deployed in 12.5% and 4.2% and sometimes in 25% and 33.2% of the participating centers, respectively 22 . Anterior lines were not frequently performed in any center but sometimes in 25% 22 .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…In our study, we were able to create and block all anterior, roof and mitral isthmus lines with PFA. In the recently published Manifest PF survey of 24 European centers, roof lines and mitral isthmus lines were frequently deployed in 12.5% and 4.2% and sometimes in 25% and 33.2% of the participating centers, respectively 22 . Anterior lines were not frequently performed in any center but sometimes in 25% 22 .…”
Section: Discussionmentioning
confidence: 99%
“…In the recently published Manifest PF survey of 24 European centers, roof lines and mitral isthmus lines were frequently deployed in 12.5% and 4.2% and sometimes in 25% and 33.2% of the participating centers, respectively. 22 Anterior lines were not frequently performed in any center but sometimes in 25%. 22 This survey supports our data for feasibility of this PFA-guided ablation strategy.…”
Section: Ablation Lines and Lesion Durabilitymentioning
confidence: 99%
See 2 more Smart Citations
“…Moreover, the rate of short- and mid-term adverse events was very low. In the latest report of the MANIFEST-PF registry, PVI with PFA was accomplished in 99.9% of patients, with a low rate of major complications [ 95 ]. However, antral PVI may not be adequately achieved through PFA, since an insufficient isolation of the left anterior antral PV segments and enlarged LA isolation areas on the posterior segments was detected by Bohnen et al [ 96 ].…”
Section: Atrial Fibrillation Catheter Ablationmentioning
confidence: 99%