Multianalyte On-Chip Native Western Blotting

Abstract: We introduce and characterize multiplexed native Western blotting in an automated and unified microfluidic format. While slab gel Western blotting is slow and laborious, conventional multiplexed blotting ("reblotting": probing one sample with multiple antibodies) requires even more resources. Here we detail three key advances that enable an automated and rapid microfluidic alternative to slab gel reblotting. First, we introduce both assay and microdevice designs that integrate protein blotting against multiple… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
77
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 46 publications
(80 citation statements)
references
References 59 publications
3
77
0
Order By: Relevance
“…A custom built, computer controlled, 8 channel current or voltage programmable high voltage power supply (HVPS) was used. 38 Quantization of the assay results was achieved by calculating the area under the curve (AUC) values of the fluorescence intensity profiles obtained along the channel. Both the intensity profile extractions and the total signal integration for the selected region of interest (ROI) were performed in ImageJ.…”
Section: Imaging Data Acquisition and Chip Operationmentioning
confidence: 99%
“…A custom built, computer controlled, 8 channel current or voltage programmable high voltage power supply (HVPS) was used. 38 Quantization of the assay results was achieved by calculating the area under the curve (AUC) values of the fluorescence intensity profiles obtained along the channel. Both the intensity profile extractions and the total signal integration for the selected region of interest (ROI) were performed in ImageJ.…”
Section: Imaging Data Acquisition and Chip Operationmentioning
confidence: 99%
“…This technique also has been applied to CE and MCE formats, e.g., an application to two-dimensional MCE [23], immunoaffinity gel electrophoresis [24,25], chemical immobilization onto a monolithic column for affinity electrophoretic analysis [26], encapsulation of the biomolecules based on the sol-gel technologies [27], and so on [28], realizing the specific and rapid analyses of the biogenic compounds with small consumptions of samples/reagents. Recently, many researchers focus on the encapsulation of ligands into the hydrophilic gels since the affinity of the encapsulated ligands is well kept as compared to the other chemical immobilization techniques.…”
Section: Affinity Capturing and Related Techniquesmentioning
confidence: 99%
“…Second, the robust biosensor systems should be able to have continual monitoring capability every few hours or days for kinetics analysis of biomarkers over extended periods. Most of the current biosensing systems based on enzyme‐linked immunosorbent assay (ELISA),9 surface plasmon resonance,10 mass spectrometry (MS),11 surface enhanced Raman spectroscopy,12 as well as electrochemical (EC) and fluorescence‐based detection13 inherently suffer from surface saturation upon binding of target molecules, limiting their multiple use in accurate and continual analysis of biomarkers 14. To regenerate the probe, the entire interface must be reconstructed, which often requires harsh, time‐consuming stripping protocols 15.…”
Section: Introductionmentioning