2017
DOI: 10.3174/ajnr.a5332
|View full text |Cite
|
Sign up to set email alerts
|

Multicenter Experience with FRED Jr Flow Re-Direction Endoluminal Device for Intracranial Aneurysms in Small Arteries

Abstract: Deployment of the FRED Jr is safe and effective in the treatment of intracranial aneurysms located in small vessels.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
51
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(54 citation statements)
references
References 23 publications
1
51
0
2
Order By: Relevance
“…A recent metaanalysis of coil embolization techniques for distal ACA aneurysms reported morbidity and mortality of 15% and 9%, respectively 92) . The recent development of low-profile braided FDS and additional design advances in FDS and their delivery systems my make distal artery aneurysm more amenable to this promising technique 82) .…”
Section: Distal Artery Aneurysmsmentioning
confidence: 99%
See 1 more Smart Citation
“…A recent metaanalysis of coil embolization techniques for distal ACA aneurysms reported morbidity and mortality of 15% and 9%, respectively 92) . The recent development of low-profile braided FDS and additional design advances in FDS and their delivery systems my make distal artery aneurysm more amenable to this promising technique 82) .…”
Section: Distal Artery Aneurysmsmentioning
confidence: 99%
“…Recent advances like duallayered weave and new cell configurations target improved wall apposition, more uniform cell configuration, improved and uniform radial force, and improved delivery and resheathing. The FRED Jr (Microvention, Tustin, CA, USA) was recently introduced specifically to address the challenges of using FDS in small distal arteries 82,93) . While it retains the dual-layered construction of its namesake, it leverages a 36wire inner layer and 16-wire outer layer to facilitate use in vessels from 2-3 mm in diameter.…”
Section: Future Directions For Fdsmentioning
confidence: 99%
“…Overall, 22 included studies were retrospective series, 1,2,4,[11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28] whereas 5 articles were prospective series (details in On-line Table 3). [29][30][31][32][33]…”
Section: Quality Of Studiesmentioning
confidence: 99%
“…To date, there are limited data on both the FRED Jnr and the Silk Vista Baby. Möhlenbruch et al [31] published their multicenter results of 42 patients with 47 aneurysms. The FRED Jnr was successfully deployed in 39/42 (93%) and the vast majority of the aneurysms treated arose from the anterior circulation (42/47, 89.4%) with 18 aneurysms located on the MCA and 24 located on the ACA.…”
Section: Discussionmentioning
confidence: 99%