1999
DOI: 10.1246/bcsj.72.2253
|View full text |Cite
|
Sign up to set email alerts
|

Multielement Determination of Trace Elements in Coastal Seawater by Inductively Coupled Plasma Mass Spectrometry with Aid of Chelating Resin Preconcentration

Abstract: The multielement determination of trace elements in coastal seawater by inductively coupled plasma mass spectrometry has been investigated with the aid of chelating resin preconcentration. First, each coastal seawater sample (250 ml) was treated with a chelating resin (Chelex 100) at pH 6 for preconcentration of trace elements. After filtration with a glass filter, the resin on the filter was carefully rinsed with 8 ml of 1 M ammonium acetate solution. Then, trace elements adsorbed on the resin were eluted wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
34
0

Year Published

2001
2001
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 56 publications
(36 citation statements)
references
References 30 publications
2
34
0
Order By: Relevance
“…These concentration levels were quite reasonable, compared to the literature values as the concentrations of Mo, U, and V dissolved in seawater, 2 although some fluctuations of the concentrations were observed, probably because of their poor recoveries in chelating resin preconcentration. 5,6 It can be seen from Fig. 2 that the dissolved concentration of W was at the 0.01 µg l -1 level in the open-sea area, which was lower by ca.…”
Section: Concentration Variations Of Oxoanion-forming Metals In Surfamentioning
confidence: 92%
See 3 more Smart Citations
“…These concentration levels were quite reasonable, compared to the literature values as the concentrations of Mo, U, and V dissolved in seawater, 2 although some fluctuations of the concentrations were observed, probably because of their poor recoveries in chelating resin preconcentration. 5,6 It can be seen from Fig. 2 that the dissolved concentration of W was at the 0.01 µg l -1 level in the open-sea area, which was lower by ca.…”
Section: Concentration Variations Of Oxoanion-forming Metals In Surfamentioning
confidence: 92%
“…5 The chelating resin (Chelex 100) in 100 -200 mesh was purchased from Bio-Rad Laboratories (Lichmond, CA, USA). The resin was soaked in 5 M HCl for about one week, changing every day, and washed with pure water before use.…”
Section: Chemicalsmentioning
confidence: 99%
See 2 more Smart Citations
“…The experimental conditions were chosen after optimizing the instrumental parameters as in previous studies. 11,12 The wavelengths of the emission lines and mass numbers (m/z) for the analyte elements used in the ICP-AES and ICP-MS measurements, respectively, are given in Table 2. In the ICP-MS measurement, matrix effects due to major elements in the sample were corrected by the internal-standard method, 13 where Ge, Rh, Re and Tl were used as the internal-standard elements.…”
Section: Instrumentsmentioning
confidence: 99%