2007 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems 2007
DOI: 10.1109/nems.2007.352144
|View full text |Cite
|
Sign up to set email alerts
|

Multilayer Electrodes DEP Chip for Single-cell Level Impedance Measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
3
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 4 publications
2
3
0
Order By: Relevance
“…Thus, the device does not need an extra AC signal for particle trapping. The impedance measurement results reported by Chuang et al [10] show that the impedance magnitude of a single 16 µm particle is higher than that of the PBS, which is consistent with the results in the present work. However, the impedance variation in this work is much higher, making it much easier to distinguish the impedance of a particle from that of PBS solution.…”
Section: Impedance Measurement Of Single Particlesupporting
confidence: 93%
See 2 more Smart Citations
“…Thus, the device does not need an extra AC signal for particle trapping. The impedance measurement results reported by Chuang et al [10] show that the impedance magnitude of a single 16 µm particle is higher than that of the PBS, which is consistent with the results in the present work. However, the impedance variation in this work is much higher, making it much easier to distinguish the impedance of a particle from that of PBS solution.…”
Section: Impedance Measurement Of Single Particlesupporting
confidence: 93%
“…Chuang et al [10] presented a 3D microcavity structure for trapping particles and impedance measurement. However, an extra AC signal, which may influence measurement results, is required for the dielectrophoresis (DEP) force to move and trap a single particle in the microcavity.…”
Section: Impedance Measurement Of Single Particlementioning
confidence: 99%
See 1 more Smart Citation
“…Subsequently, Suehiro 71 , et al proposed a similar structure where the electrode system consisted of two glass plates, on which parallel strip electrodes were fabricated, placed together with a spacer between them so that their electrodes face each other and cross at right angles to form the grid. Such structures have also been reported by many groups [72][73][74][75][76][77][78] . Recently, a novel system with thin film vertical electrodes deposited on both sides of the microchannel for DEP trapping has been reported by Wang 79 , et al The vertical metal electrodes with different length ratios were fabricated by electroplating on the SU-8 microchannel to generate the non-uniformity of the electric field for particle manipulation.…”
Section: Step(d)supporting
confidence: 78%
“…In 2007, Zhang et al [ 5 ] proposed a different design for impedance measurement with single-cell resolution; he separated the electrodes for individual purposes of DEP trapping and impedance measurement; thus, long-term monitoring of dynamic process of endothelin-1-induced cardiomyocyte hypertrophy could be achieved. In the meanwhile, Chuang [ 6 , 7 ] demonstrated a DEP chip with multilayer electrodes and a micro-cavity array for trapping single cells in a micro-cavity by negative DEP force and sequentially sensing their impedance. In Chuang’s work, the impedance measurement of trapped cells in a micro-cavity did not have to apply DEP force due to the enhancement of the positioning and immobilization by the microstructure effects.…”
Section: Introductionmentioning