2012
DOI: 10.1016/j.ophtha.2011.08.039
|View full text |Cite
|
Sign up to set email alerts
|

Multiple Radial Midpupil Lid Distances: A Simple Method for Lid Contour Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
43
0
5

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 54 publications
(48 citation statements)
references
References 13 publications
0
43
0
5
Order By: Relevance
“…Recently, a method for analyzing eyelid contour using digital photography instead of the traditional handheld ruler has been increasingly used. 3,10,11 The method suggested by Milbratz et al 3 provides a new direction for conveniently comparing eyelid contour. Many methods for measuring multiple radial MPLD have been reported.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, a method for analyzing eyelid contour using digital photography instead of the traditional handheld ruler has been increasingly used. 3,10,11 The method suggested by Milbratz et al 3 provides a new direction for conveniently comparing eyelid contour. Many methods for measuring multiple radial MPLD have been reported.…”
Section: Discussionmentioning
confidence: 99%
“…This study analyzes the upper and lower eyelid contours of normal adults and patients with TED using a software program that measures multiple radial midpupil lid distance (MPLD). 3 …”
mentioning
confidence: 99%
“…12 It is agreed that some patients sought treatment for preoperative contour anomalies. The method used is an extension of the time-honored measurement of the eyelid margin height at the noon position.…”
Section: Discussionmentioning
confidence: 99%
“…All techniques published to correct upper eyelid retraction are minor variations of weakening of the levator palpebrae superioris (LPS) and Müller's muscle. In the present study, a new method was used to measure eyelid contour 12 to analyze the shape of the upper eyelid in a series of patients with Graves orbitopathy who had undergone surgery for eyelid retraction correction. Although well-known in the oculoplastic literature, 5,11 these contour abnormalities have never been analyzed in a quantitative manner.…”
mentioning
confidence: 99%
“…Alguns autores descrevem o uso da DMR1, analisando o contorno palpebral e também as diferentes posições do olhar 112,113 . Nesta pesquisa, utilizou-se como parâmetro a DMR1 em PPO, que permitiu uma análise mais objetiva, por ser mais fácil a observação do reflexo pupilar em lugar de seu centro na prática diária e por ser amplamente utilizada na semiologia habitual da ptose palpebral.…”
Section: Exemplos De Respostas Aos Testes Nos Três Gruposunclassified