2015
DOI: 10.1109/jsen.2015.2460011
|View full text |Cite
|
Sign up to set email alerts
|

Multisensor Portable Meter for Environmental Applications

Abstract: In recent years the development of information and communication technologies (ICT) has notably improved the water management processes, but the technologies for water quality control still leave much scope for improvement. Specially, in-situ and in-line water monitoring has an increasing interest in order to take decisions at real time. The main drawbacks of the current portable meters are their high cost and their high power consumption. In this work it is proposed a portable compact meter for measuring simu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 19 publications
0
11
0
Order By: Relevance
“…A detailed explanation of the electronic design, software for data collection, and global performance of this equipment is presented in [23]. …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A detailed explanation of the electronic design, software for data collection, and global performance of this equipment is presented in [23]. …”
Section: Methodsmentioning
confidence: 99%
“…These sensors were also characterized before the analysis using the multisensor meter. The response characteristics are reported in [23], including the conductivity calibration and the ORP test obtained with the four-electrode sensors.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Multiplexed electrochemical analysis on-chip was performed with a portable homemade multi-parametric system fabricated at the IMB-CNM. 25 Briefly, the system generated and received signals from four micro-sensors: (i) the resistance temperature detector (RTD) Pt-100 (Pico Technology, St Neots, UK); (ii) the four-wire conductivity sensor, where an alternating current at 5 kHz is applied to the two external electrodes and the current is recorded between the two internal electrodes; (iii) the ORP sensor, which is directly connected to the acquisition module and provides potential values by comparison with the reference electrode; and (iv) the amperometric sensor, a three-electrode microsensor system where the electrical voltage is fixed between the reference and the working electrodes while recording the current flowing between the working and the counter electrodes. The device incorporated two amperometric terminals that could be used simultaneously for glucose and hydrogen peroxide determination.…”
Section: Equipmentmentioning
confidence: 99%
“…1. It employs two compact low-power multisensor meters [3], [4] to read out an array of microdevices formed by one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes, together with six ISFETs sensitive to pH, Figure 1.…”
Section: Demonstration Setupmentioning