2015
DOI: 10.1007/s11051-015-2884-x
|View full text |Cite
|
Sign up to set email alerts
|

Nanomaterial release characteristics in a single-walled carbon nanotube manufacturing workplace

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…• Class I: size-resolved, time-resolved instruments whose particle detection capability is based on optical or electrical mobility, such as the Scanning Mobility Particle Sizer (SMPS) [30,31], Fast Mobility Particle Sizer (FMPS) [32][33][34], Optical Particle Counter (OPC) [35][36][37] and Electrical Low-Pressure Impactor (ELPI) [38,39]. • Class II: size-integrated, time-resolved instruments, such as the Condensation Particle Counter (CPC) [30,36] and Nanoparticle Surface Area Monitor (NSAM) [40,41].…”
Section: Instruments and Techniquesmentioning
confidence: 99%
“…• Class I: size-resolved, time-resolved instruments whose particle detection capability is based on optical or electrical mobility, such as the Scanning Mobility Particle Sizer (SMPS) [30,31], Fast Mobility Particle Sizer (FMPS) [32][33][34], Optical Particle Counter (OPC) [35][36][37] and Electrical Low-Pressure Impactor (ELPI) [38,39]. • Class II: size-integrated, time-resolved instruments, such as the Condensation Particle Counter (CPC) [30,36] and Nanoparticle Surface Area Monitor (NSAM) [40,41].…”
Section: Instruments and Techniquesmentioning
confidence: 99%
“…With aethalometers, it is possible to get time-resolved data (approximately in the range of minutes, depending on concentration) showing, for example peak exposures. Previously, eBC measurements have been used in workplaces to detect CNTs in the emission zone (EZ) or background zone (BGZ) ( Han et al , 2008 ; Lee et al , 2010 ; Hashimoto et al , 2013 ; Ji et al, 2013 , 2015 ; Kim et al , 2016 ). Thus, eBC may be used as a proxy for EC; however, the mass concentration of CNTs may be underestimated, as CNT materials may have different optical properties compared with other common EC materials such as diesel soot ( Hashimoto et al , 2013 ).…”
Section: Introductionmentioning
confidence: 99%
“…Many of the studies which have been conducted were at research facilities where CNTs were produced (Maynard et al, 2004;Bello et al, 2008a;Tsai et al, 2009;Methner et al, 2010;Ogura et al, 2010) and handled ( Johnson et al, 2010;Methner et al, 2010;R'mili et al, 2010) and where advanced composites containing CNTs were produced (Cena and Peters, 2011;Fleury et al, 2013) or machined (Bello et al, 2008b). Additional studies have been conducted at industrial sites where CNTs or products utilizing CNTs were manufactured (Han et al, 2008;Lee et al, 2010Lee et al, , 2014Lee et al, , 2015Dahm et al, 2012Dahm et al, , 2015Wang et al, 2011;Methner et al, 2012;Takaya et al, 2012;Fonseca et al, 2014;Hedmer et al, 2014;Heitbrink et al, 2015;Ji et al, 2015). Only two studies have employed the recommended sampling and analytical method for quantifying the CNT REL.…”
Section: Introductionmentioning
confidence: 99%